MX410/MX412 System Manual Menu Descriptions
61189500L1-1B PRELIMINARY 5-49
Daily PM Thresholds MenuThe Daily PM Thresholds menu (see Figure 5-33) displays DS1 performance monitoring thresholds data in a tabular format. This menu is used to set the performance monitoring threshold levels and enable or disable an alarms if the threshold is exceeded.Figure 5-33. Daily PM Thresholds MenuThe Daily PM Thresholds menu options are shown in Table 5-27.Table 5-27. Daily PM Thresholds Menu Options
Option Description Function
1ES-L This option sets the ES-L threshold value. The available
threshold range is (1-65535). The default value is 648.
2CV-P (ESF mode) This option sets the CV-P ESF threshold value. The available
threshold range is (1-1048575). The default value is
132,960.
3CV-P (SF mode) This option sets the CV-P SF threshold value. The available
threshold range is (1-1048575). The default value is 691.
4ES-P This option sets the ES-P threshold value. The available
threshold range is (1-65535). The default value is 648.
5SES-P This option sets the SES-P threshold value. The available
threshold range is (1-65535). The default value is 100.
6SAS-P This option sets the SAS-P threshold value. The available
threshold range is (1-65535). The default value is 17.
7CSS-P This option sets the CSS-P threshold value. The available
threshold range is (1-65535). The default value is 691.
MX410 MM/DD/YY HH:MM
Active Alarms: CRITICAL MAJOR ID: MX410
Daily PM Thresholds
Threshold Alarm
1 - ES-L : 648 Enabled
2 - CV-P (ESF mode) : 132960 Enabled
3 - CV-P (SF mode) : 691 Enabled
4 - ES-P : 648 Enabled
5 - SES-P : 100 Enabled
6 - SAS-P : 17 Enabled
7 - CSS-P : 4 Enabled
8 - UAS-P : 10 Enabled
9 - Restore ALL DS1 Threshold Defaults
10 - Enable ALL DS1 Threshold Alarms
11 - Disable ALL DS1 Threshold Alarms
Selection : '?' - System Help Screen