ADTRAN none quick start NetVanta Serial Dial Backup Interface Module DIM, P/N 1200886L1, Features

Models: none

1 2
Download 2 pages 47.95 Kb
Page 1
Image 1
Quick Start Guide

®

Quick Start Guide

For more detailed documentation, visit us online at www.adtran.com.

NetVanta Serial Dial Backup Interface Module (DIM)

P/N 1200886L1

 

 

SLOT 1 NET/D BU

WAN--DDST1 DSX-1

DBU

SPECIFICATIONS

LAN

CONSOLE

 

INSTALLATION INSTRUCTIONS

1.Remove power from the base unit.

2.If the Network Interface Module (NIM) is already in the NetVanta chassis, release the pins at both edges of the NIM faceplate and slide the module out of the chassis.

3.Carefully align the P1 connector on the NIM with the J1 connector on the Serial DIM. Using only fingertip pressure so that neither circuit board bends or flexes, ensure that the connectors are firmly seated. Secure the Serial DIM to the NIM using the screws and standoff posts supplied.

4.Slide the NIM with the Serial DIM attached into the NetVanta option slot until the NIM is firmly seated against the chassis.

5.Secure the pins at both edges of the NIM.

6.Connect the cables to the associated device(s)

7.Complete installation of the base unit.

Features

5-pin RS-232 interface via host RJ-45 DBU connector

 

Modem flow control support via CTS

 

Communication with external modem via AT commands

Compliance

FCC Part 15 Class A, EN 55022 Class A, EN 55024

 

EN 61000-3-2, EN 61000-3-3

 

IEC 60950, EN 60950, UL/CUL 60950, AS/NZS 60950

Physical

Dimensions: 2.3-inch W x 2.75-inch D

 

Operating Temperature: 0°C to 50°C

 

Storage Temperature: -20°C to 70°C

 

Relative Humidity: Up to 95 percent, noncondensing

An RJ-45 to DB-9 adapter cable (P/N 1200887L1) is required to connect to the external modem.

NetVanta modules should be installed only in

NetVanta Series products.

For NetVanta modules with outside plant connections, ensure that all cables are removed from the module before installing or removing it from the NetVanta chassis.

SERIAL DBU CONNECTION PINOUTS

Pin

Name

 

 

1, 2

Unused

3

CTS

4

TXD

5

RXD

6

GND

7

DCD

8

Unused

Important: For additional details on product features, specifications, installation, and safety, refer to the appropriate Hardware Installation Guide on the ADTRAN OS System Documentation CD shipped with the base unit and available online at www.adtran.com.

Quick Start Guide, 61200886L1-13B, July 2006

Technical Support 1-888-4ADTRAN (1-888-423-8726)

Copyright © 2006 ADTRAN, All Rights Reserved

Page 1
Image 1
ADTRAN none quick start NetVanta Serial Dial Backup Interface Module DIM, P/N 1200886L1, Quick Start Guide, Specifications