ADTRAN OPTI-T200 Provisioning Options, Account Provisioning, Software Upgrade, Compliance, Code

Models: OPTI-T200

1 2
Download 2 pages 60.58 Kb
Page 2
Image 2
TOTAL ACCESS OPTI - T200

TOTAL ACCESS OPTI - T200

PRICING AND AVAILABILITY 800.827.0807 TECHNICAL SUPPORT 800.726.8663 RETURN FOR REPAIR 256.963.8722 www.adtran.com 61184400L1-22A

PROVISIONING OPTIONS

Upon initial installation, the OPTI-T200 uses factory default settings. To provision the OPTI-T200, connect a terminal emulator via the RS-232 (DB-9) connector on the front panel. The terminal must be VT100 compatible and set for 9600 bps, 8 data bits, no parity and 1 stop bit. The following table lists the provisioning settings and their default values. The settings are retained in a nonvolatile memory device in case of power loss to the OPTI-T200.

Options

Settings (Default in Bold)

Service State

In Service, Out Of Service-Unassigned, Out Of Service-Maintenance

DS3 Provisioning

 

 

DS3 Interface

Enable, Disable

DS3 Line Build Out

Short, Long

Signal Fail (SF) Thresh

1x10-3, 1x10-4, 1x10-5

Signal Degrade (SD) Thresh

1x10-5, 1x10-6, 1x10-7, 1x10-8, 1x10-9

Clock Source (TX)

1.

Receive OC-3

 

2.

Free Run

CLLI Code

User definable up to 20 characters

Network Provisioning

 

 

IP Address

User Defined

 

Format = x.x.x.x where x = 0–255

Subnet Mask

User Defined

 

Format = x.x.x.x where x = 0–255

Default Gateway

User Defined

 

Format = x.x.x.x where x = 0–255

Telnet Menu Port

User defined = 0–65535 (23)

Telnet (TL-1) Port

User defined = 0–65535 (2001)

Time and Date

User Defined

Mount Location

Central Office, Remote

Account Provisioning

See the Account Provisioning section to the right of this table.

Restore Factory Defaults

 

 

Software Upgrade

TFTP, XModem, YModem

NOTE: To navigate through the menus, select the desired entry and press Enter. To work backward in the menus, press the Escape key. Some entries can be changed in only the Out-of-Service – Maintenance mode.

ACCOUNT PROVISIONING

1.Account 1

a)User Name – User Defined, up to 15 characters

b)Password – User Defined, up to 15 characters

c)Permission Level – Disabled, Read Only, Read-Write, Administrator

d)Delete Account

2.Account 2 – Same options as Account 1

3.Account 3 – Same options as Account 1

4.Account 4 – Same options as Account 1

5.Account 5 – Same options as Account 1

6.Account 6 – Same options as Account 1

7.Account 7 – Same options as Account 1

8.Account 8 – Same options as Account 1

9.Account 9 – Same options as Account 1

10.Account 10 – Same options as Account 1

SOFTWARE UPGRADE

Software download for the local OPTI-T200 is provided using XModem or YModem via the craft port or TFTP, XModem or YModem via Ethernet. Software download to a remote OPTI-T200 is accomplished either from the CO OPTI-T200 craft port or its Ethernet port. The download is carried over the DCC channel. TFTP is supported from only the Ethernet interface, and both systems would require IP addresses.

COMPLIANCE

This product intended for use in Restricted Access Areas only, and is intended to be installed in a Type “B” or “E” enclosure. This product complies with UL 60950.

Code

Input

Output

Power Code (PC)

F

C

Telecommunication Code (TC)

Installation Code (IC)

A

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by ADTRAN could void the user’s authority to operate this equipment.

WARRANTY

ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service. Warranty information can be found at www.adtran.com/warranty. U.S. and Canada customer Faxback: 877-457-5007, Document 414.

Page 2