239 H2R

 

ENHANCED PSD 239 H2R

JOBAID

 

61221045L2-22A

 

 

0111

STATUS LEDs

LOOPBACK AND CONTROL CODES

 

CLEI: T1R6VJWD_ _

DSL NET Off

No synchronization with the H2TU-C

Solid Green

Synchronized with an SNR margin greater than the user defined SNR

 

Margin Alarm Threshold

Fast Blinking

(Blinking 3 times per second) Attempting to synchronize with the

Green

H2TU-C

Slow Blinking (Blinking 1 time per second) Synchronized with an SNR margin greater

Green

than the user defined SNR Margin Alarm Threshold and the pulse

 

attenuation is greater than the user defined Loop Attenuation Alarm

 

Threshold

Solid Yellow

Synchronized with an SNR margin greater than 0 dB but less than the user

 

defined SNR Margin Alarm Threshold

Slow Blinking Synchronized with an SNR margin greater than 0 dB but less than the user Yellow (1/sec) defined SNR Margin Alarm Threshold and the pulse attenuation is greater

than the user defined Loop Attenuation Alarm Threshold

FUNCTION

CODE

RESPONSE

ARM (in-band)

11000 (binary)

H2TU-C and H2R will arm and the H2TU-R will loop-up toward the network

 

 

 

ARM (ESF Data Link)

FF48 (hex) or 1111 1111

 

 

0100 1000 (binary) sent

H2TU-C and H2R will arm and the H2TU-R will loop-up toward the network

 

in the Facility Data Link

H2TU-R will only loop if the NIU option is enabled

 

 

 

Disarm (in-band)

11100 (binary)

All units are removed from the armed state and loopbacks will be released

 

 

 

Disarm (ESF Data Link)

FF24 (hex) or 1111 1111

 

 

0010 0100 (binary) sent in

All units are removed from the armed state and loopbacks will be released

 

the Facility Data Link

 

H2TU-C Network Loop-Up1

D3D3 (hex) or

If received while in an armed state, the H2TU-C will loop toward the network,

 

1101 0011 1101 0011

transmit 2 seconds of AIS(all 1s) followed by 5 seconds of loop code (D3 hex)

 

(binary)

and then 231 logic errors will be injected toward the network. The logic errors

 

 

will continue to be sent in 231 bit error bursts every 20 seconds as long as the

 

 

pattern continues to be detected by the H2TU-C. When the pattern is removed,

 

 

the unit will remain in loopback.

Loopdown w/out

9393 (hex) or

Automatically releases without disarming any H2TU-C and H2R that may be in

disarming2

1001 0011 1001 0011 (binary) loopback toward the network.

 

Solid Red

Synchronized with an SNR margin of 0 dB

 

Slow Blinking

(Blinking 1 time per second) Synchronized with an SNR margin of 0 dB

 

Red

and the pulse attenuation is greater than the user defined Loop

 

 

Attenuation Alarm Threshold

DSL CUST Off

No synchronization with the H2TU-R

 

Solid Green

Synchronized with an SNR margin greater than the user defined SNR

 

 

Margin Alarm Threshold

 

Fast Blinking

(Blinking 3 times per second) Attempting to synchronize with the

 

Green

H2TU-R

 

Slow Blinking

(Blinking 1 time per second) Synchronized with an SNR margin greater

 

Green

than the user defined SNR Margin Alarm Threshold and the pulse attenu

 

 

ation is greater than the user defined Loop Attenuation Alarm Threshold

 

Solid Yellow

Synchronized with an SNR margin greater than 0 dB but less than the user

 

 

defined SNR Margin Alarm Threshold

 

Slow Blinking

Synchronized with an SNR margin greater than 0 dB but less than the user

 

Yellow (1/sec) defined SNR Margin Alarm Threshold and the pulse attenuation is greater

 

 

than the user defined Loop Attenuation Alarm Threshold

 

Solid Red

Synchronized with an SNR margin of 0 dB

 

Slow Blinking

(Blinking 1 time per second) Synchronized with an SNR margin of 0 dB

 

Red

and the pulse attenuation is greater than the user defined Loop

 

 

Attenuation Alarm Threshold

LL/RL

Green

Indicates a loopback at the H2R toward the H2TU-R is active

 

Yellow

Indicates a loopback at the H2R toward the H2TU-C is active

Loopback Query1

D5D5 (hex) or

Allows one to query the devices at any given time to determine whether any

 

1101 0101 1101 0101 (binary) units are in loopback. If D5 hex is received while in a loopback state, the unit in

 

 

question will transmit the logic error count toward the network using the same

 

 

methodology as identified in each of the loop-up descriptions (231 BE = H2TU-C,

 

 

10 BE = H2R1, 200 BE = H2R2 and 20 BE = H2TU-R).

Query Loop Parameters

DBDB

If the units are armed, and the H2TU-C is in network loopback, errors are

 

(1101 1011 1101 1011)

injected into the DSX-1 signal upon detection of the query loop parameters

 

 

pattern. As long as a pattern continues to be sent, errors are injected again

 

 

every 20 seconds. The number of errors injected each time depends on the

 

 

current status of signal quality and pulse attenuation parameters on each

 

 

loop. 111 errors are injected if all HDSL receiver [points (H2TU-C LP1/LP2,

 

 

H2R #1 NET LP1/LP2, H2R #1 CST LP1/LP2, H2R #2 NET LP1/LP2, H2R #2 CST

 

 

LP1/LP2, and H2TU-R LP1/LP2) indicate pulse attenuation is 30 dB or lower and

 

 

signal quality (margin) is 6 dB or higher. 11 errors at a time are injected if any

 

 

of the 12 receiver points indicate pulse attenuation is greater than 30 dB

 

 

and/or signal quality (margin) is less than 6 dB.

Loopback Time-Out

D5D6 (hex) or

If received during the armed state and prior to loopback initiation, the loopback

Override1, 3

1101 0101 1101 0110

timeout override feature will automatically disable loopback timeout, i.e., the

 

(binary)

loopback will not timeout after the 120 minute default period. As long as the

 

 

units remain armed, the timeout will remain disabled. When the units are

 

 

disarmed, the loopback timeout will once again return to the default value.

Span Power Disable1, 3

6767 (hex) or

If received during an armed state (must not be in loopback), the H2TU-C will remove

 

0110 0111 0110 0111 (binary)

span power toward the line. As long as the pattern is received, the span power will

 

 

remain disabled. Once the pattern is no longer received, the H2TU-C will reactivate

 

 

span power. All units will then re-train and return to the disarmed state.

H2R1 Network Loop-up1

C741

If an H2R is present and units armed, the H2R will loop up toward network, 2

 

(1100 0111 0100 0001)

seconds of AIS (all 1s) will be sent, 5 seconds of data will pass, and then 10 bit

 

 

errors will be injected into the DSX-1 signal. As long as the pattern continues to

 

 

be sent, 10 errors will be injected every 20 seconds. When the pattern is

 

 

removed, the unit will remain in loopback. If the pattern is reinstated, the

 

 

injection of 10 bit errors will resume at 20-second intervals.

H2TU-R Loop-up1

C742

ESF facility Datalink: ESF only; when sent from the network, an H2TU-R

 

(1100 0111 0100 0010)

network loopback is activated and a 20-bit error confirmation is sent. When

C A U T I O N !

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

ENHANCED PSD

The Enhanced PSD 239 H2R , P/N 1221045L2, must be used in conjunction with the Enhanced PSD T200 H2TU-R, P/N 1222026L9. This H2R will not function with any other H2TU-Rs. The Enhanced PSD T200 H2TU-R will function with all versions of the ADTRAN H2R, but the enhanced spectral performance will only be achieved using the Enhanced PSD 239 H2R.

CARD EDGE PIN ASSIGNMENTS

1

 

 

 

GND

 

 

 

 

 

 

 

NC

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

CUSTOMER

 

 

 

 

4

 

 

 

 

 

 

 

 

SIDE 1

5

 

 

 

NETWORK

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

7

 

 

 

NC

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

NETWORK

 

 

 

 

9

 

 

 

 

 

 

 

 

SIDE 2

01

 

 

 

GND

 

 

 

 

 

 

 

 

 

 

 

 

BYPASS

11

 

 

 

CUSTOMER

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

sent from the customer, an H2TU-R customer loopback is activated with a

20-bit error confirmation.

1Units must be armed with 11000b or FF48h before this code will work.

2In order to behave like an NIU, the H2TU-R will not loop down from the network side with 9393h.

3This code will be detected only if the units are armed AND there are NO loopbacks active.

NOTE: All codes listed above must be sent for a minimum of 5 seconds in order for them to be detected and acted upon.

*If NIU is enabled, then the H2TU-R can be in network loopback when the H2TU-C or H2R loop-up codes are sent.

HANDLING PRECAUTIONS REQUIRED.

■ For a complete Installation and Maintenance Practice faxback: (877) 457-5007, Document # 742. Please have your fax number available. ■

Page 1
Image 1
ADTRAN PSD 239 H2R manual Loopback and Control Codes, Enhanced PSD