ADTRAN SHDSL E1 specifications T1 Port Statistics Definitions, Maintenance, Specifications

Models: SHDSL E1

1 10
Download 10 pages 33.21 Kb
Page 9
Image 9
Table 6. T1 Port Statistics Definitions

Table 6. T1 Port Statistics Definitions

Statistic

Framing Mode

Definition

 

 

 

Errored Seconds (ES)

Unframed

LOS condition or BPV’s > 0

 

 

 

 

SF

LOS or LOF condition, or if BPV’s > 0 or FE’s > 0

 

 

 

 

ESF

LOS or LOF condition, or if BPV’s > 0 or FE’s > 0

 

 

 

Severely Errored Seconds (SES)

Unframed

LOS condition or BPV’s > 1544

 

 

 

 

SF

LOS or LOF condition, or if BPV’s > 1544 or if FE’s > 8

 

 

 

 

ESF

LOS or LOF condition, or if BPV’s > 1544 or if FE’s > 8

 

 

 

Unavailable Seconds (UAS)

N/A

If 10 continuous SES’s, then UAS

 

 

If 10 continuous seconds with no SES’s, then no UAS

 

 

 

Code Violations Count (CVC)

Unframed

If BPV’s > 0

 

 

 

 

SF

If BPV’s > 0 or FE’s > 0

 

 

 

 

ESF

If BPV’s > 0 or FE’s > 0

 

 

 

6. MAINTENANCE

The SHDSL T1/E1 NTU requires no routine mainte- nance for normal operation.

ADTRAN does not recommend that repairs be attempted in the field. Repair services may be obtained by returning the defective unit to ADTRAN. Refer to the Warranty and Customer Service section for further information.

7. SPECIFICATIONS

Specifications for the SHDSL T1/E1 NTU are detailed in Table 7.

8.WARRANTY AND CUSTOMER SERVICE

ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifi- cations or fails while in service. Warranty information can be found at www.adtran.com/warranty.

Table 7. SHDSL T1/E1 NTU Specifications

Environmental

Operating Temperature: –0°C to 55°C

Storage Temperature:

–40°C to 85°C

Relative Humidity:

90 percent maximum @

 

50°C, noncondensing

Maximum Current Draw:

0.074 A maximum

 

@ Ð48 VDC

Maximum Heat

3.55 watts

Dissipation:

 

Physical

Dimensions:

5.625 in. H x .625 in. W x

 

6.0 in. D

Weight:

< 1 lb.

 

 

 

Part Number

 

 

SHDSL T1/E1 NTU

1225236L1

Module:

 

 

 

61225236L1-5A

Issue 1, August 2003