5. OPERATION
Test Capabilities
The SHDSL T1/E1 NTU has the following test capabil- ities:
•Self diagnostics
•Local loopbacks
•EOC initiated remote loopbacks
•Inband remote loopback detection (E1 mode only)
•Internal bit error rate tester (BERT)
Self Diagnostics
The SHDSL T1/E1 NTU performs self diagnostic tests of its Read Only Memory (ROM), Random Access Memory (RAM), LEDs, and
Local and Remote Loopbacks
For troubleshooting purposes, the SHDSL T1/E1 NTU provides three types of loopback tests.
1.Dual sided
2.Network
3.Customer
Inband Loopback Detection
Inband remote loopback response is supported on the E1 port. The SHDSL T1/E1 NTU supports V.54 and PN127 inband signalling protocols.
BERT
The SHDSL T1/E1 NTU contains a
Customer Port
The SHDSL T1/E1 NTU operates in either E1 mode or T1 mode.
E1 Mode
In E1 mode the port features are as follows:
•Carries information at the rate of 2.048 Mbps
•Uses CCS framed format with or without
•Operates in either Alternate Mark Inversion (AMI) or
•Provides programmable timeslot idle pattern
•Supports
•Displays additional status information via a local VT100 management screen
See Table 5 for E1 port statistics definitions.
T1 Mode
In T1 mode the port features are as follows:
•Carries information at the rate of 1.544 Mbps
•Uses Superframe Format (SF) or Extended Super- frame Format (ESF)
•Operates in either Alternate Mark Inversion (AMI) or Bipolar
•Provides programmable timeslot idle pattern
•Monitors the Facility Data Link (FDL) for loopback commands
•Displays additional status information via a local VT100 management screen
See Table 6 for T1 port statistics definitions.
Issue 1, August 2003 | 5 |