Advantech C-Band Hub-mountSSPA/ SSPB, Technical Specifications, 100W, 150W, 200W, 125W, 250W

Models: SSPA/ SSPB

1 2
Download 2 pages 44.8 Kb
Page 2
Image 2
C-Band Hub-mount SSPA/ SSPB

C-Band Hub-mount SSPA/ SSPB

Technical Specifications

60W

80W

100W

125W

150W

200W

250W

Electrical Characteristics

 

 

 

 

 

 

 

Availability in this series

 

 

 

 

 

 

 

CS, CR

CL,CP,CI,CX

Note 1

Note 1

Output power (PSAT)

+48 dBm

+49 dBm

+50 dBm

+51 dBm

+52 dBm

53 dBm

53 dBm

Output power (P1dB) min.

+47 dBm

+48 dBm

+49 dBm

+50 dBm

+51 dBm

52 dBm

53 dBm

Power gain @ maximum gain setting

56 dB min

 

60 dB min

 

65

65

Operating frequency range

See table A on front page

 

 

 

 

 

Max input power without damage

+10 dBm

 

 

 

 

 

 

Gain slope

0.6 dB max over 40 MHz

 

 

 

 

 

Gain flatness over 600 MHz

±1.0 dB max

 

 

 

 

 

Gain variation over temperature

±1.5 dB over full operating temperature range

 

 

 

Gain variation over 24 hours

±0.25 dB max at constant temperature & drive level

 

 

 

Gain adjustment range

20 dB min (0.1 dB resolution)

 

 

 

 

Input return loss

18 dB

 

 

 

 

 

 

Output return loss

19 dB

 

 

 

 

 

 

Noise power density

-70 dBm/Hz max in TX band

 

 

 

 

 

-150 dBm/Hz max in 3.4 –4.2 GHz RX band

 

 

 

Spurious at rated power

-65 dBc max

 

 

 

 

 

Harmonics at rated power

-60 dBc max

 

 

 

 

 

AM/PM conversion at rated power

2.5 /dB max (at P1dB),

 

 

 

 

 

 

1°/dB max. at 3 dB back-off

 

 

 

 

Third order IMD (2 tones 5 MHz apart)

-26 dBc max at 3 dB total back-off from rated P1dB

 

 

 

Group delay

Linear:

0.02 nsec/MHz max.

 

 

 

 

 

Parabolic: 0.003 nsec/MHz2 max.

 

 

 

 

 

Ripple:

1.0 nsec p-p max.

 

 

 

 

Residual AM

0-10 kHz

 

-45 dBc

 

 

 

 

(F* - frequency in kHz)

10 kHz - 500 kHz

-20 (1.25+log F*) dBc

 

 

 

 

500 kHz - 1 MHz

-80 dBc

 

 

 

 

Power Requirements

 

 

 

 

 

 

 

AC input voltage

110/220 VAC auto ranging (47-63 Hz)

 

 

 

 

Power consumption (nominal)

490W

550W

630W

710W

800W

950W

1100

Mechanical Characteristics

 

 

 

 

 

 

 

Dimensions (L x W x H)

18.50” x 9.80” x 9.21” (46.99 x 24.89 x 23.39 cm)

 

 

 

Weight (with mounting frame)

32 kg (70 lbs)

 

 

 

 

 

Interfaces: RF input

Type N (Female)

Redundancy

MS3112E14-12P

RF output CPR137 contact

Output sample port

Type N (Female)

Discrete port

MS3112E16-26P

(for CL series - CPR187)

AC Line

MS3102R16-10P

RS-485

MS3112E10-6P

 

Environmental Conditions

 

 

 

Temperature

Operating

-30

C to +55

C Option 1: -40 C to +55 C; option 2: -50 C to +50 C

 

Storage

-55

C to +85

C

Humidity

 

100%, condensing (2” rain/hour)

Altitude

 

10,000’ AMSL, derated 2°C/1,000’ from AMSL

Note 1: Please refer AWMA-4000C®product datasheet

NORTH AMERICA

EUROPE

SOUTH AMERICA

An ISO 9001 : 2008 Company

USA

UNITED KINGDOM

BRAZIL

 

Tel: + 1 703 788-6882

Tel: +44 1480 357 600

Tel: +55 11 3054 5701

 

Fax: +1 703 788-6511

Fax: +44 1480 357 601

Fax: +55 11 5041 4026

 

info.usa@advantechwireless.com

info.uk@advantechwireless.com

info.brazil@advantechwireless.com

 

CANADA

RUSSIA & CIS

ARGENTINA

 

Tel: +1 514 420-0045

Tel: +7 495 967 1859

Tel: +54 11 4731 1034

Ref.: PB-AWMA-C-60-250-11025

Fax: +1 514 420-0073

Fax: +7 495 967 30 24

Cel: +54 911 4492 5601

info.canada@advantechwireless.com

info.russia@advantechwireless.com

info.argentina@advantechwireless.com

 

 

 

 

www.advantechwireless.com

 

Specifications are subject to change without prior notice

Page 2
Image 2
Advantech manual C-Band Hub-mountSSPA/ SSPB, Technical Specifications, 100W, 150W, 200W, 125W, 250W, Power Requirements

FAQ

What are the electrical characteristics of C-Band Hub-mount SSPA/SSPB?

You can find electrical characteristics such as availability in the series, CS, CR, CL, CP, CI, CX, output power PSAT, power gain, operating frequency range, and more in the technical specifications section.

Where can I find the power requirements for C-Band Hub-mount SSPA/SSPB?

You can find the AC input voltage and power consumption nominal under the power requirements section.

What are the environmental conditions for C-Band Hub-mount SSPA/SSPB?

The operating temperature, storage temperature, humidity, and altitude specifications can be found under the environmental conditions table.