AEG 2642-6 KG manual Changing the light bulb

Models: 2642-6 KG

1 22
Download 22 pages 37.4 Kb
Page 20
Image 20
Changing the light bulb

Heavy build up of frost, pos- sibly also on the door seal.

Door seal is not air tight (possibly after changing over the hinges).

Carefully warm the leaking sections of the door seal with a hair dryer (not hotter than approx. 50 ¡C). At the same time shape the war- med door seal by hand such that it sits correctly.

Unusual noises.

Appliance is not level.

Readjust the feet.

 

The appliance is touching

Move the appliance slightly.

 

the wall or other objects.

 

The compressor does not start immediately after chan- ging the temperature set- ting.

A component, e.g. a pipe, on the rear of the appliance is touching another part of the appliance or the wall.

This is normal, no error has occurred.

If necessary, carefully bend the component out of the way.

The compressor starts after a period of time.

Water on the floor or on sto- Water drain hole is blocked. rage shelves.

See the "Cleaning and Care" section.

Changing the light bulb

Warning! There is a risk of electric shocks! Before changing the light bulb, switch off the appliance and unplug it, or pull the fuse or the cir- cuit breaker.

Light bulb data: 220-240 V, max. 15 W

1.To switch off the appliance, turn the temperature regulator to position "0".

2. Unplug the mains plug.

3. To change the light bulb, unscrew the light cover.

4. Unhook the light bulb cover as shown.

5. Change the defective light bulb.

6. Refit the light bulb cover and the screw.

D731

7.Put the refrigerator back into operation.

39

Page 20
Image 20
AEG 2642-6 KG manual Changing the light bulb