First decide which functioning version is better for you.

If you decide to use the hood in exhausting version we suggest to position the upper section of the chimney so that the oulet slots are not visible once installation has ended, on the contrary if is decided to use the hood in recycling version BE SURE that the side with slots is up (see also A-B- C sequence on on Fig. 6).

Insert the frame, that holds controls, grease filter and lamps, in the mo- tor housing using proper rails and fix each other with two 3x9 screws (1- 2-3).

Sign the wall with a center line, this will aid mounting procedure (4), position the template so that the mid line printed on the template mat- ches with the center line previously signed, the lower side of the temp- late corresponds to the lower side of the hood once mounted (5).

Drill two holes Ø 8mm and fix the support bracket with two wall plugs and screws (6).

Hang the hood (7) adjust its position (8-9)and from the inside of the hood sign one point for definitive fixing (10), remove the hood and drill an hole Ø 8mm (11), fit a wall plugs, hang the hood again and fix it definitively with a screw (12).

Drill two holes Ø 8mm on the upper side close to the ceilling (13), fit two wall plugs and fix the chimney support with two screws (14).

In case the hood is to be used in Recycling version, mount the deflector F on the chimney support with four screws 2,9x6,5 and fit an exhausting pipe (15) to connect deflector to the outlet hole B of the hood.

In case the hood is to be used in exhausting version, then the deflector must not be mounted and fit an exhausting pipe (15) to connect outlet hole B of the hood to the outside.

Make electrical connection (16), but leave the hood disconnected from the home general electric panel.

Connect lamps and control panel to the motor housing (17).

Insert the vapour catcher on the motor housing and fix it with four screws M4x35 (18).

Model 3010D has an additional part that can be mounted to the first part fixed on step 18 before or after this step, choose the convenience, fixing between this two parts must be done with four screws.

Fix the chimney first up (19a) to the chimney support (19b), then on the bottom (20a) to the upper side of the frame (20b) using four screws 2,9x6,5.

Connect the hood the the home general electric panel and check if the hood work properly.