Installation and connection instructions

Water Drainage

The appliance drain hose should hook into a standpipe, the hook in the drain hose is formed using the plastic “U-Piece“ supplied. The standpipe should have an internal diameter of approximately 38 mm (see dia- gram) thus ensuring there is an air break between the drain hose and standpipe.

Important! It is essential to lay the drainage hose without kinks.

When discharging into a stand- pipe ensure that the top of the curve in the hose end is no more than 90 cm (35.4’’) and no less than 60 cm (23.6’’) above floor level.

The upright standpipe should have a minimum, length of

30 cm (12’’) from the bottom of the elbow to the top of the pipe (see diagram). Make sure that it is designed in such a way that the end of the drain hose cannot be covered with water.

Longer drain hoses are available in lengths of 2.7 and 4 metres from your AEG Service Force Centre.

53

Page 53
Image 53
AEG 84749 manual Water Drainage