Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath.

Important! The plug must still be accessible after the appliance has been installed. The appliance should not be connected to the electrical supply by means of an extension cable. In case that the electrical cable has to be replaced, please contact your local Service

Force Centre.

Warning! A cut off plug inserted into a 13 amp socket is a serious safety (shock) hazard. Ensure

that it is disposed of safely.

Noises During Operation

The following noises are characteristic of refrigeration appliances:

Clicks

Whenever the compressor switches on or off, a click can be heard.

Humming

As soon as the compressor is in operation, you can hear it humming.

Bubbling/Splashing

When refrigerant flows into thin tubes, you can hear bubbling or splashing noises. Even after the compressor has been switched off, this noise can be heard for a short time.

Regulations, Standards, Guidelines

This appliance was designed for household use and was manufactured in accordance with the appropriate standards. The necessary measures in accordance with appliance safety legislation regulations (GSG), accident prevention regulations for refrigeration appliances (VBG 20) and the regulations of the German Society of Electrical Engineers (VDE) were observed in the manufacture of this appliance. The refrigerant circuit has been checked for leaks.

This appliance is in accordance with the following EUguidelines:

73/23/EWG dated 19 February 1973 - low voltage guidelines.

89/336/EWG dated 3 May 1989

(including guideline change notice 92/31/EWG) - EMV guideline

96/57 EEC - 96/09/03 (Energy Efficiency Directive) and its subsequent amendments

Technical Terminology

Refrigerant

Liquids that can be used to a generate a cooling effect are known as refrigerants. They have a relatively low boiling-point, indeed so low, that the warmth from the food stored in the fridge or freezer can cause the refrigerant to boil and vaporise.

Refrigerant Circuit

Closed circulation system that contains the refrigerant. The refrigerant circuit comprises primarily of an evaporator, a compressor, a condenser and pipe work.

Evaporator

The refrigerant is evaporated in the evaporator. Similar to all other liquids, refrigerant requires heat to evaporate. This heat is removed from the interior of the appliance, as a result the interior is cooled. The evaporator is therefore located inside the appliance or placed in foam immediately behind the inner wall and thus not visible.

Compressor

The compressor looks like a small drum. It is driven by a built-in electric motor and is mounted on the base of the appliance at the rear. The task of the compressor is to draw in vaporised refrigerant from the evaporator, to compress it, and to pass it on to the condenser.

Condenser

The condenser normally has the form of a grid. The refrigerant com-pressed in the compressor is liquefied in the condenser. During this process, heat is released to the surrounding air at the surface of the condenser. The condenser is mounted on the base of the appliance.

A/AE/4-2. (08.)

10

Page 10
Image 10
AEG A 75100 GA3 manual Noises During Operation, Regulations, Standards, Guidelines, Technical Terminology

A 75100 GA3 specifications

The AEG A 75100 GA3 is a powerful and efficient integrated dishwasher that is designed to bring convenience and exceptional performance into your kitchen. Known for its sleek design and cutting-edge technologies, this model stands out in the crowded market of household appliances.

One of the defining features of the AEG A 75100 GA3 is its impressive capacity. With space for up to 13 standard place settings, this dishwasher can easily accommodate the needs of a medium to large household. Its flexible interior layout includes adjustable racks and folding plate holders, allowing users to maximize space for pots, pans, and awkwardly shaped dishes.

AEG has incorporated several innovative technologies into the A 75100 GA3 to enhance cleaning efficiency. Notably, the Turbo ProClean feature utilizes a high-pressure wash system to ensure that even stubborn dirt and grime are effectively removed. This technology is particularly effective for heavily soiled items, leaving them spotless after each cycle.

The appliance also boasts the AirDry technology, which automatically opens the door at the end of the wash cycle. This feature allows for natural airflow to circulate and dry your dishes more efficiently, ensuring they come out gleaming and free from moisture, while also reducing energy consumption by not requiring additional heat for drying.

In terms of energy efficiency, the AEG A 75100 GA3 is rated A++ in terms of energy efficiency, making it an eco-friendly choice for the conscientious consumer. Its intelligent sensors monitor the load and adjust the amount of water and energy used accordingly, promoting sustainability without compromising on performance.

The user-friendly digital display and control panel make it easy to select from the variety of wash programs, including Eco, Intensive, and Quick cycles. Each program is designed to optimize water and energy usage while catering to different cleaning needs.

Noise level is another important aspect of this model, operating at a whisper-quiet 47 decibels. This low noise level allows you to run the dishwasher at any time of day without disrupting conversations or activities in your home.

In summary, the AEG A 75100 GA3 combines modern design with advanced technologies and energy-efficient features, making it an excellent choice for anyone looking to upgrade their kitchen appliances. With its large capacity, innovative cleaning solutions, and quiet operation, it ensures exceptional performance and convenience for everyday dishwashing tasks.