AEG G20 manual 7&+1,&$/$7$, 167$//$7,211276

Models: G20

1 17
Download 17 pages 62.58 Kb
Page 4
Image 4

,167$//$7,21￿ $1￿ 6(59,&,1*￿ ,16758&7,216￿ 7+(￿ )2//2:,1*￿ 6(&7,21 /,676￿7+(￿,167$//$7,21￿5(*8/$7,216￿$1'￿5(48,5(0(176

All gas appliances must be installed by a competent person in accordance with the current Gas Safety (Installation and Use) Regulations 1994 (as amended) or the rules in force and in accordance with the manufacturers instructions, failure to do so could lead to prosecution

The following are the relevant Codes of Practice and British Standards.

BS 8303 1986

BS 5440 Pt1 1990 & Pt2 1989The Building Regulations issued by the

BS1251 1987

BS 5871 Pt2 1991 & Pt3 1991Department of the Environment. The

BS 6891 1988

BS 6461 Pt1 1984

Building Standards Scotland)(Consolidation)

BS 715 1989

BS 1289 Pt1 1986

Regulations issued by the Scottish Development

BS 7566 Pts 1-4 1992

 

Department.

7(&+1,&$/￿'$7$

Overall height of fire

Minimum height of opening required Maximum height of opening Minimum width of opening required Maximum width of opening with spacer Forward projection from opening

(With controls cover)

Min depth of openings TYPE OF GAS G20 Only GAS INPUTS (Gross)

Main Injector Type

Pilot Assembly

GAS CONNECTION

WEIGHT

=614 mm

=550 mm

=590 mm

=395 mm

=470 mm

=140 mm

See Figs 1-8

Supply Pressure 20 mbar +/- 1mbar (Cold)

Maximum 5.42 kW (18500 Btu/h)

Minimum 2.34 kW (8000 Btu/h)

Pilot 0.26 kW (890 Btu/h)

Bray Cat 82/380

Or Stereomatic 046/19/196/68M

SIT Oxy/Pilot NG 9022

8 mm O/D Tube

22 kg

Note: None of the materials used in the manufacture of this appliance contain asbestos.

,167$//$7,21￿127(6

Care should be taken to ensure when the appliance is installed into a Pre-cast flue, the chimney breast is lined to prevent the plaster etc, cracking through excessive temperatures.

A certain amount of discolouration (blueing) may be seen on the stainless steel combustion chamber, this is normal due to the temperatures produced in the fire bed.

A hearth must always be provided, a minimum of 340mm and a minimum of 150mm either side of the fire opening with a minimum thickness of 12mm and a perimeter height of 50mm. This is to deter combustible materials, carpets etc, being placed on the hearth.

The area under the firebox must have a minimum non-combustible thickness of 25mm.