5.1Specifications

MODELL

 

PROTECT A. 1000

 

PROTECT A. 1400

 

 

 

 

 

Type

 

1000 VA / 600 W

 

1400 VA / 840 W

 

 

 

 

UPS-input

Input voltage

220 Vac / 230 Vac / 240 Vac

 

 

 

 

Input voltage range

170 – 280 Vac

 

without battery mode

 

 

 

 

Frequency (auto

50 / 60 Hz ± 5 Hz

 

selection)

 

 

 

UPS-output

Rated output voltage

220 Vac / 230 Vac / 240 Vac

 

/AVR-technology

 

 

 

 

Rated output voltage

 

±10%

 

in battery mode

 

 

 

 

Frequency in battery

50 / 60 Hz ± 1 Hz

 

mode

 

 

 

 

Transfer time at mains

2 – 6 ms (typical)

 

outage

 

 

 

 

Output Waveform

Modified sinewave

 

 

 

 

 

Battery

Type

12 V / 7 Ah x 2

 

12 V / 9 Ah x 2

 

 

 

 

 

 

Autonomy time

 

3 min

 

(full Load)

 

 

 

 

Recharge time (to

 

8 h

 

90% of rated capacity)

 

 

 

Indicator

AC mode

Green LED lighting

 

LED bar graph (LED 2 to 5) indicates the load capacity

 

 

 

 

 

 

Backup mode

Green LED flashing

 

LED bar graph (LED 2 to 5) indicates the battery capacity

 

 

 

 

 

 

Fault

Red LED lighting

 

 

 

Acoustic alarm

Backup mode

Sounding every 10 seconds

 

 

 

 

Low battery

Sounding every second

 

 

 

 

Overload

Sounding every 0.5 second

 

 

 

 

Battery replacement

Sounding every 2 seconds

 

 

 

 

Fault USP

Continuously sounding

 

 

 

 

 

Protection

 

Discharge, overcharge, and overload protection

 

 

 

 

 

General data

Size

140 x 180 x 370

 

W x H x D (mm)

 

 

 

 

Weight (kg)

14 kg

 

14,5 kg

 

 

 

 

 

Operating temperature

0°- 40°C

 

 

 

 

 

range

Relative humidity: 0 – 90 % (non-condensing)

 

 

 

 

Audible noise

< 45 dB (A)

 

(1 m distance)

 

 

 

Communication

Interfaces

USB and RS232 for status and measurement levels

 

 

 

 

Shutdown-Software

Included for all typical operating systems

 

 

 

 

 

(on CD)

(e.g. Windows, Linux, Mac)

 

 

 

 

 

16