AEG SCN71800S0 manual Problem, Possible cause, Solution, There is no cold air circulation in

Models: SCN71800S0

1 32
Download 32 pages 28.49 Kb
Page 17
Image 17

 

 

 

 

 

What to do if…

 

 

 

 

 

 

 

 

17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Problem

 

Possible cause

 

Solution

 

 

 

 

 

 

 

 

 

 

 

The room temperature is too

 

Decrease the room temperature.

 

 

 

high.

 

 

 

 

 

 

 

 

 

 

 

 

The compressor does not

 

This is normal, no error has oc-

 

The compressor starts after a pe-

 

start immediately after

 

curred.

 

riod of time.

 

 

pressing the FROSTMATIC

 

 

 

 

 

 

 

or COOLMATIC button, or

 

 

 

 

 

 

 

after changing the tem-

 

 

 

 

 

 

 

perature.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water flows on the rear

 

During the automatic defrosting

 

This is correct.

 

 

plate of the refrigerator.

 

process, frost defrosts on the

 

 

 

 

 

 

 

rear plate.

 

 

 

 

 

 

 

 

 

 

 

 

 

Water flows into the re-

 

The water outlet is clogged.

 

Clean the water outlet.

 

 

frigerator.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Products prevent that water

 

Make sure that products do not

 

 

 

flows into the water collector.

 

touch the rear plate.

 

 

 

 

 

 

 

 

 

The temperature in the

 

The temperature regulator is not

 

Set a higher/lower temperature.

 

appliance is too low/high.

 

set correctly.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The door is not closed correctly.

 

Refer to "Closing the door".

 

 

 

 

 

 

 

 

 

 

 

The product temperature is too

 

Let the product temperature de-

 

 

 

high.

 

crease to room temperature be-

 

 

 

 

 

fore storage.

 

 

 

 

 

 

 

 

 

 

 

Many products are stored at the

 

Store less products at the same

 

 

 

same time.

 

time.

 

 

 

 

 

 

 

 

 

The temperature in the re-

 

There is no cold air circulation in

 

Make sure that there is cold air

 

frigerator is too high.

 

the appliance.

 

circulation in the appliance.

 

 

 

 

 

 

 

 

 

The temperature in the

 

Products are too near to each

 

Store products so that there is

 

freezer is too high.

 

other.

 

cold air circulation.

 

 

 

 

 

 

 

 

 

 

There is too much frost.

 

Food is not wrapped correctly.

 

Wrap the food correctly.

 

 

 

 

 

 

 

 

 

 

 

 

The door is not closed correctly.

 

Refer to "Closing the door".

 

 

 

 

 

 

 

 

 

 

 

 

The temperature regulator is not

 

Set a higher temperature.

 

 

 

 

set correctly.

 

 

 

 

 

 

 

 

 

 

 

 

Upper or lower square is

 

An error has occurred in meas-

 

Call your service representative

 

shown in the temperature

 

uring the temperature.

 

(the cooling system will continue

 

Display.

 

 

 

to keep food products cold, but

 

 

 

 

 

temperature adjustment will not

 

 

 

 

 

be possible).

 

 

 

 

 

 

 

 

 

dEMo appears on the Dis-

 

The appliance is in demonstra-

 

Keep pressed approximately 10

 

play.

 

tion mode (dEMo).

 

sec. the OK button since a long

 

 

 

 

 

sound of buzzer is heard and the

 

 

 

 

 

Display shut off for a short while:

 

 

 

 

 

appliance start works regularly.

 

 

 

 

 

 

 

 

Page 17
Image 17
AEG SCN71800S0 manual Problem, Possible cause, Solution, There is no cold air circulation in, circulation in the appliance