Installation 19
Positioning
Install this appliance at a location where the ambient temperature corresponds to the cli- mate class indicated on the rating plate of the appliance:
Climate class |
| Ambient temperature |
|
|
|
SN |
| +10°C to + 32°C |
|
|
|
N |
| +16°C to + 32°C |
ST |
| +16°C to + 38°C |
|
|
|
T |
| +16°C to + 43°C |
|
|
|
Electrical Connection
CAUTION!
Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person.
WARNING!
This appliance must be earthed.
The manufacturer declines any liability should these safety measures not be observed.
The wires in the mains lead are coloured in accordance with the following code:
| Green and Yellow: | Earth |
1 | ||
| Brown: | Live |
3 | ||
| Blue: | Neutral |
5 |
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:
1.Connect the wire coloured green and yellow to the terminal marked either with the letter “E“ or by the earth symbol or coloured green and yellow.