29

= Main menu (appears after plugging in the LBA)

Main menu

Parameters

Submenu

XR

YR

XA

YA

Menu

Operating mode

TAKT/FC

VAR /PA

SSSD/FC-PA

Res

No.ctrld.phase 123

Load R,RL,transf.,C

Service

OFF,ON

ASM OFF,

ON, OFF

MoSi

OFF,R,S

Afterpulse

OFF,ON

TDS

OFF,ON

Neutral

OFF,ON

Hardware parameters

Curr.conv. xxxxx Volt.conv. xxxx X501-3 1-2,2-3,3-4

Type current xxxxx Type voltage xxxx Burden load. xxx,xx

Frequency

Date yyyymmdd

Time hhmmss Cntr. data log. x Peak value xxxxx

SW_FA_1-6 list_L1-3_FA DAC1-3_FA TI_FA KP_FA Puls.s.off OFF,ON

K1 closed-c OFF,ON

Monitoring

Relative/Absolute Undercurrent OFF/ON

Overcurrent

OFF/ON

Monit. L2

OFF/ON

Monit. L3

OFF/ON

Uline

max

xxxV

Uline

max

xxxV

Temperature

Messages

Monitoring Relativ

Undercurrent xx %

Overcurrent xx % Value unequal ZERO!

Monitoring absolut

Undercurrent xx A Overcurrent xxx A ZERO!

next

submenu

*

6

7

Default

User

Remarks

Value

Value

 

TAKT

 

Operating mode selection full oscillation clock principle

 

 

Operating mode selection phase-angle principle

 

 

Operating mode selection Soft-Start-Soft-Down

 

 

Reserve

1

 

Number of phases controlled (power paths)

 

 

R: without startup ramps, C: like R, only for TAKT

OFF

 

Operation without controls or limitations

OFF

 

Display for ASM process

 

 

Uses analog output 2, terminal 33

OFF

 

R: ramp, S: steer

ON

 

Only for 3-phase and VAR

OFF

 

Only for 3-phase and VAR

OFF

 

Only for 3-phase

100Transformation ratio ü:1

16 Transformation ratio ü:1

Voltage adjustment measurement range 3 see chapter

 

Voltage transformer

type

See name plate

type

See name plate

1 Ohm

current transformer adjustment incl. tolerances

 

Only display of the mains frequency

 

Input and display

 

Input and display

 

Current count of data logger counter 1 to 16

65000

Peak current value at which instant impulse lock

 

shall be set (in Ampere)

*

 

*

 

*

 

*

 

*

 

ON

IMAB: shutdown of the Power Controller in case of fault

ON

K1RU: switching open contact/closed contact (only K1)

 

Display/setting of the monitoring values

R/A

 

 

x

 

y

1)absolute limiting value, see Fig. 4

1)absolute limiting value, see Fig. 4

1)change of absolute limiting value is only possible if the corresponding relative limiting value are zero/255.

2)change of absolute limiting value is only possible if the corresponding relative limiting value are zero/5000.

Cursor is in front of the selected value

Cursor is in front of the selected value

* password protection

Page 29