4.3Programming The CL4424 units

1.Connect a CL4424 unit to the serial communications port on the PC.

2.Connect the power supply to the CL4424 unit. Make sure the Pwr LED is on.

3.Start the CL4424 Configuration Utility.

4.Select the COM Port that is connected to the CL4424 unit on the PC Settings section.

5.Select the Interface Baud Rate of the CL4424 unit. All CL4424 units are shipped with a default rate of 115,200 bps (unless units have been pre-configured to match specific serial settings). If the Interface Baud Rate of the CL4424 unit is changed as described in Section 4.2 Changing CL4424 Settings, then PC Setting Baud Rate must be set to the same Baud Rate to allow proper programming of the units.

6.Select the System Configuration for the CL4424 network, Point-to-Point(one Server and one Client) or Point-to-Multipoint(one Server and multiple Clients).

7.Select Read Radio to display the current settings of the CL4424 unit.

8.Change desired settings.

9.After all changes have been made, select Write Radio to save the changes.

10.Cycle Power to the unit after all changes has been saved. This will set the CL4424 unit to its normal mode of operation.

6/21/2005

19

Page 19
Image 19