7 Rev. 10©1999 - 2006 DMC Co., Ltd.
A
TP/AST Series Product Specifications
3. Reliability Condition

3-1. Temperature Condition

§ Temperature Condition Test
Following test are performed in the condition with no dew condensation:
Cold Test: Tested after leaving the parts in -30°C±3°C for 240 hours and in the room temperature
for 2 hours.
Heat Test: Tested after leaving the parts in 80°C±3°C for 240 hours and in the room temperature for
2 hours.
Humidity Test: Tested after leaving the parts in the temperature 60°C±3°C, humidity 90 to 95% for 240
hours and in the room temperature for 2 hours.
Cycle Test: Tested after 5 cycles of leaving the parts in the temperature -30°C±3°C for 1 hour and in
the room temperature for 0.5 hours, then leaving the parts in the temperature 70°C±3°C
for 1 hour and in the room temperature for 0.5 hours.
Judgement: Must satisfy the following:
Activation Force: Within ±50% of the specification.
Linearity: Must satisfy the specification.
Terminal Resistance: Must satisfy the specification.
Insulation Resistance: Must satisfy the specification.
Appearance: Must satisfy the specification.
4. Recommended Connector

4-1. Recommended Connector

Part No. Pins Pitch
KCA-K4R 4 pin Double-sided 1.25mm