SERVICING - WARNING
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
Orifices |
|
A Wok burner |
|
B Large Burner |
|
C Medium Burners |
|
D Small Burner | A valve bypass screw |
Ratings |
|
| Natural Gas |
|
| Propane Gas |
|
| |
|
|
|
|
|
|
| |
Cooktop |
| Orifice | Screw |
| Orifice | Screw | |
Wok burner | 15,000Btu/hr | internal 110 | 82 | 15,000Btu/hr | internal 71 | 49 | |
|
| ||||||
external 166 | external 93 | ||||||
|
|
|
|
| |||
Large Burner | 12,000Btu/hr | 170 | 70 | 12,000Btu/hr | 106 | 38 | |
|
|
|
|
|
|
| |
Medium Burners | 9,200Btu/hr | 150 | 53 | 8,000Btu/hr | 84 | 31 | |
Small Burner | 5,000Btu/hr | 107 | 43 | 4,200Btu/hr | 61 | 22 | |
|
|
|
|
|
|
|
Gas burner inputs based on Gross Calorific Value
Ovens | Left hand Multifunction Oven | Right hand Fan Oven |
Fan element | 2.5kW | 2.5kW |
|
|
|
Top element | 1.2kW |
|
Browning Element | 1.15kW |
|
|
|
|
Bottom element | 1.0kW |
|
Broiler | 2.3kW |
|
Maximum total electrical load at 240V 7.4kW (approximate total including oven lights, oven fan etc.)
15