Verification kits are used to verify the performance specifications of an Agilent 8510 system. All kits include a precision Zo airline, mismatched airline, and fixed attenuators. Measured data and uncer- tainties traceable to the U.S. National Institute of Standards and Technology (NIST) are included with each kit. Compliance with MIL-STD 45662A is available for an extra charge (Option 1BP). Option 002 provides verification kit data on magnetic tape for use with the 8510A/B.

Choose a verification kit for each connector type required.

Verification kit

Connector type

Frequency range (GHz)

 

 

 

85051B

7 mm

0.045 to 18

 

 

 

85053B

3.5 mm

0.045 to 26.5

 

 

 

85055A

Type-N

0.045 to 18

 

 

 

85057B

2.4 mm

0.045 to 50

 

 

 

R11645A

WR-28

26.5 to 40

 

 

 

Q11645A

WR-22

33 to 50

 

 

 

U11645A

WR-19

40 to 60

 

 

 

V11645A

WR-15

50 to 75

 

 

 

W11645A

WR-10

75 to 110

 

 

 

Test port cables and adapters

Test port cables and adapter sets are available for various connector types. Special test port adapter sets convert the rugged ports of the network ana- lyzer test set to the desired connector interface.

Each kit contains two adapters, one male and one female. Both the cables and the test port adapters have one special female connector which is designed to connect directly to the 3.5 mm test port (2.4 mm for 8517B). This side of the cable or adapter can only be connected to the test set port and cannot be mated to a standard 3.5 mm (or

2.4mm) male connector. Choose one of the config- urations shown.

Configuration A. This cable arrangement is for appli- cations where the device under test is connected directly to the test set port. This setup offers the best mechanical rigidity for device connection. To adapt the test set port (port 1) to the device under test, choose the appropriate special adapter set. In addition to converting the test port to the desired interface, these adapters also function as “test port savers” which protect the test set from damage and wear due to heavy use.

For Agilent 8514B/8515A/85110A test sets (3.5 mm rugged test port connectors)

 

 

Connector type

 

 

(on device side of

 

Cables/adapters

cable/adapter)

 

 

 

For 3.5 mm

85131C semi-rigid cable or

3.5 mm (f)

devices

85131E flexible cable

3.5 mm (f )

 

85130D adapter set

3.5 mm (m and f)

 

 

 

For 7 mm

85132C semi-rigid cable or

7 mm

devices

85132E flexible cable

7 mm

 

85130B adapter set

7 mm

 

 

 

For Type-N

Use 7 mm cables and the 7-mm-

 

devices

to-Type-N adapters included

 

 

in the 85054B/D Type-N

 

 

calibration kit

 

 

 

 

For Agilent 8517B test sets

(2.4 mm rugged test port connectors)

 

 

Connector type

 

 

(on device side

 

Cables/adapters

of cable/adapter)

 

 

 

For 2.4 mm

85133C semi-rigid cable or

2.4 mm (f)

devices

85133E flexible cable

2.4 mm (f )

 

85130G adapter set

2.4 mm (m and f)

 

 

 

For 3.5 mm

85134C semi-rigid cable or

3.5 mm (f)

devices

85134E flexible cable

3.5 mm (f )

 

85130F adapter set

3.5 mm (m and f)

 

 

 

For 7 mm

85135C semi-rigid cable or

7 mm

devices

85135E flexible cable

7 mm

 

85130E adapter set

7 mm

 

 

 