Agilent Technologies E8267D Agilent PSG Vector Signal Generator Options, Choose a frequency range

Models: E8267D

1 8
Download 8 pages 20.13 Kb
Page 2
Image 2
Agilent PSG Vector Signal Generator Options

Standard product includes installation guide, electronic documentation set (CD-ROM), adapters, and country specific power cord.

High output power (Option 1EA) and step attenuator (Option 1E1) are standard features in the

E8267D vector signal generator.

Agilent PSG Vector Signal Generator Options

Step 1. Choose a frequency range

All frequency range options support underrange to 100 kHz. However, performance specifications are not provided between 100 kHz and 250 kHz.

Ordering number

Description

Purpose

Requires

E8267D-520

Frequency range from 250 kHz to 20 GHz

Selects the maximum frequency of the

 

 

 

signal generator.

 

E8267D-532

Frequency range from 250 kHz to 31.8 GHz

Selects the maximum frequency of the

 

 

 

signal generator.

 

E8267D-544

Frequency range from 250 kHz to 44 GHz

Selects the maximum frequency of the

 

 

 

signal generator.

 

Step 2. Choose spectral purity

Ordering number

Description

Purpose

Requires

Standard

Standard spectral purity

Provides low phase noise.

 

E8267D-UNX

Ultra low phase noise

Improves phase noise performance at

 

 

 

carrier frequency offsets ranging from

 

 

 

1 Hz to 10 kHz.

 

E8267D-1EH

Improved harmonics below 2 GHz

Improves harmonic performance for carrier

 

 

 

frequencies below 2 GHz.

 

Step 3. Choose modulation

Ordering number

Description

Purpose

Requires

Standard

CW signal generation,

Generates continuous wave (CW)

 

 

vector (IQ) modulation capability

signals and can modulate IQ waveforms

 

 

 

provided by the optional internal baseband

 

 

 

generator (Option 602) or an external

 

 

 

baseband source

 

E8267D-UNT

AM, FM, phase modulation, and LF output

Generates analog modulated signals.

 

E8267D-UNU 1

Pulse modulation

Generates pulse modulated signals

 

 

 

(150 ns minimum pulse width).

 

E8267D-UNW 1

Narrow pulse modulation

Generates pulse modulated signals

 

 

 

(20 ns minimum pulse width).

 

Step 4. Choose ramp sweep

Ordering number

Description

Purpose

Requires

E8267D-007

Analog ramp sweep

Generates a fully synthesized ramp (analog)

 

 

 

sweep of frequency and amplitude.

 

Step 5. Choose internal baseband generator

Ordering number

Description

Purpose

Requires

E8267D-602

Internal baseband generator,

Generates arbitrary and real-time I/Q

 

 

64 Msa memory

waveforms (80 MHz of RF modulation

 

 

 

bandwidth).

 

E8267D-009

Removable flash memory

 

 

1.Option E8267D-UNU and E8267D-UNW are mutually exclusive; choose one or the other or neither. However, option E8267D-UNU can be upgraded to E8267D-UNW.