Ordering information
Example configuration:
A test system is being built that requires the following Microwave Switching:
•(qty 2) Agilent 87206B SP6T Switches
•(qty 8) Agilent N1810UL SPDT Switches
Select the quantity of distribu- tion boards for the required switches using the ordering info below:
•Qty 2 Y1152A Distribution boards to control qty 2 87206B switches.
•Qty 1 Y1150A Distribution board to control qty 8 N1810UL switches.
Notice that each Y1152A can also drive two N181x switches. Therefore if you only needed to drive 4 N1810 switches, then you could have controlled those switches via the Y1152A distribution boards already selected.
Here is the final recommended configuration:
•(qty 2) 87206B
•(qty 8) N1810UL
•(qty 1) L4445A Switch/Attenuator Driver (when ordering the L4445A, the 34945EXT is automatically added for controlling switches)
•(qty 2) Y1152A Distribution Boards
•(qty1) Y1150A Distribution Board
•Either build own cables using
We recommend that the switch be ordered with options for
24 V coils, position indicators, and socket connectors. Since
24 V latching relays are speci- fied, there is no need for an external power supply. The L4445A instrument can provide power for a single 34945EXT.