Aiphone AX Series 13710 (28 13 00) - 6
2. You can communicate with door station from telephone.
3. You can end communication at telephone. Communication also ends automatically when
set talk time limit is reached. About 10 seconds before end of call, you will hear alarm
sound on telephone.
4. Maximum duration for CO line call is 300 seconds, even if call timer is set to “Infinite”.
5. Using this function requires Viking Electronics, Inc. “K-1900-5 Hot-Line Pulse Dialer”.
6. If there are multiple calls, call from door station with highest call priority is transferred.
7. Answering at any master station during CO transfer feature will stop CO transfer.
8. There are no functions, such as for door release and dial-in, from telephone.
G. All Call (Normal Master Station Paging):
1. When you press ALL CALL button on master station, all individual master station selector
button LEDs flash slowly. You can clear undesired master station from All Call by
pressing individual master station selector button with flashing LED, which will turn off
LED. Pressing that button again makes that master station part of All Call again and
makes LED flash.
2. If you press TALK button, send LED lights up and all individual master station selector
buttons stop flashing and stay lit. Pre-tone sounds on target master stations and they can
be talked to. At this time, you cannot hear audio from other master stations.
3. Press OFF button to end. You can end call for individual master station by pressing its
OFF button.
4. All Call announcements do not go to master stations that are in use.
5. During All Call, if you press individual master station selector button on calling master
station or press individual master station selector button or TALK button on 1 of the other
master stations, communications switch to hands-free between master stations.
6. There is no function for hands-free reply from called master station during All Call mode.
7. If you press down ALL CALL button but do not start talking within 30 seconds, system
goes back to standby mode. You can also return to standby by pressing OFF button.
H. All Call (Priority Master Station Paging):
1. When you press ALL CALL button on master station, all individual master station selector
button LEDs flash slowly.
2. If you press ALL CALL button again, flash rate increases. You can clear undesired master
station from All Call by pressing individual master station selector button with flashing
LED, which will turn off LED. Pressing that button again makes that master station part of
All Call again and makes LED flash.
3. If you press TALK button, TALK LED lights up and all individual master station selector
buttons stop flashing and stay lit. Pre-tone sounds on all master stations and all can be
called. At this time, you cannot hear audio from other master stations.
4. Press OFF button to end. You can end call for individual master station by pressing its
OFF button.
5. Communication of master station being used is cancelled and All Call takes priority.
Before communication of master station being used is cancelled, you hear cancel warning
sound.
6. During All Call, if you press an individual master station selector button on calling master
station or press individual master station selector button or TALK button on one of the
other master stations, communications switch to hands-free between those two master
stations.
7. There is no function for talk back from master station receiving an All Call announcement.
8. If you press down ALL CALL button but do not start talking within 30 seconds, system
goes back to standby mode. You can also return to standby by pressing OFF button.