Aiphone IS-SS-HID-I Wiring Diagram, Testing & Operation, Specifications, Card Reader, Door Unit

Models: IS-SS-HID-I

1 2
Download 2 pages 22.82 Kb
Page 2
Image 2
WIRING DIAGRAM:

WIRING DIAGRAM:

IS-MV

 

IS-CCU

 

 

 

 

 

 

 

CAT-5e

IS-PU-UL

IS-SS-HID-I

 

 

 

CAT-5e

 

 

 

 

NO

COM

NC

To Strike

& Power

TESTING & OPERATION:

Connect the reader to the host according to the wiring table below and the host installation guide.

Wiegand Wire

Color

 

 

+ DC (10-16V)

Red

Ground

Black

Data0

Green

Data1

White

Shield Ground

Drain

Green LED

Orange

Red LED

Brown

Beeper

Yellow

Hold

Blue

---

Violet

 

 

When power is applied to the iCLASS® reader, the LED will turn RED while the beeper beeps simultaneously 3 times (the last tone is a higher frequency). The LED will then flash once after the last tone. This indicates that the microcontroller is operating properly.

Present an iCLASS ID card to the reader (hold card directly in front of reader). The LED will momentarily turn green while the beeper beeps once, indicating that the card was read successfully.

SPECIFICATIONS:

CARD READER:

 

DOOR UNIT:

 

Reader type:

R10 (Rev. C)

Terminations:

RJ45 jack for audio/video

Power Source:

10 ~ 16V DC

 

Screw terminals for door release

Current:

80mA (Avg); 300mA (peak)

Operating Temp:

14° ~ 140°F / -10° ~ 60°C

Transmit Freq.

13.56 MHz

Wiring Distance:

980’ with Cat5e/6 cable

Terminations:

Color-coded pre-wired pigtail

Dimensions:

12-3/8” H x 7” W

Wiring Distance:

500’

w/SBX-ISDVFP:

12-13/16” H x 7-1/16” W x 2-13/16” D

Operating Temp:

14° ~ 140°F / -10° ~ 60°C

 

(top), 1-13/16” D (bottom)

Operating Humidity:

5-95% relative humidity

 

 

 

non-condensing

 

 

Aiphone Corporation

1700 130th AVE NE

Bellevue, WA 98005

(425)455-0510 Fax: (425) 455-0071

FCC WARNING:

This device complies with Part 15 of the FCC rules.

Operation is subject to the following two conditions:

(1)This device may not cause harmful interference.

(2)This device must accept any interference that may cause undesired operation.

For proper regulatory compliance, the drain wire should be disconnected at the power supply end of the cable.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

The Reader is intended to be powered from a limited power source output of a previously certifed power supply

TOLL FREE TECHNICAL SUPPORT:

(800) 692-0200

E-MAIL: tech@aiphone.com

Pg. 2 IS-SS-HID-I Instr. 0311JD

Page 2
Image 2
Aiphone IS-SS-HID-I dimensions Wiring Diagram, Testing & Operation, Specifications, Card Reader, Door Unit