LE-GAnMulti-Unit Entry Stations for Open Voice Intercoms

ENTRANCE PANEL KITS (Stock)

STANDARD PRODUCTS:

LE-GA2

2-Call Entry Panel

GW-002H

Semi-flush mtg. hood (up to 4 buttons)

LE-GA3

3-Call Entry Panel

GW-002HB

Surface mtg. hood (up to 4 buttons)

LE-GA4

4-Call Entry Panel

GW-003H

Semi-flush mtg. hood (5~8 buttons)

LE-GA5

5-Call Entry Panel

GW-003HB

Surface mtg. hood (5~8 buttons)

LE-GA6

6-Call Entry Panel

 

 

LE-GA7

7-Call Entry Panel

 

 

LE-GA8

8-Call Entry Panel

STOCK MASTER STATIONS:

 

 

C-ML/A

Master station with automatic time out

S.O.P. MASTER STATIONS

LEF-5

5-call master with selective dr. release

LEM-1DL/C

Master station with manual

LEF-10

10-call master with selective dr. rel.

 

OFF button for one entry.

 

master stations.

 

Wall or desk mount

 

 

 

(Multiple masters.

POWER SUPPLIES:

 

PT-1210N for each master.)

SKK-620

6V DC, 200mA for C-ML/A masters

 

 

PT-1210N

16V AC, 10VA for LEM-1DL/C masters

LEF-3L

3-call master with selective

PS-12C

12V DC, 1A for LEF Systems

 

door release (multiple masters OK)

 

 

SYSTEM LAYOUT EXAMPLE (with C-ML/A master stations):

C-ML/AC-ML/A

SKK-620

SKK-620

2

2

2

2

LE-GA4 NOTE:

Wiring for door strike and power source for strike not shown.

Run separate 2 conductor wire from master to door strike and power.

C-ML/A

SKK-620

C-ML/A

SKK-620

ARCHITECTS/ENGINEERS’ SPECIFICATIONS:

The intercom system shall be of an open voice, selective calling type with the ability for two-way communication with the specified inside stations.

Entrance station shall be available with two to eight call buttons. Entrance station shall selectively call to the following inside master stations: C-ML/A, LEM-1DL/C, or LEF-series master stations.

Entrance panel shall be flush mount with optional weather resistant hoods available. The entrance panel shall have an aluminum faceplate, equipped with call buttons and directory strips. A surface mount box with built-in weather resistant hood shall be available.

When using C-ML/A or LEM-1DL/C master stations, each station must be powered independently with its own power source. Two room stations with separate power supplies can be used together with the LEM-1DL/C master stations. A second C-ML/A can be used, along with the DAK-2S dual master adaptor kit and separate power supplies.

The system used with the LEF system shall have the capability of adding individual door stations and multiple master stations.

System shall be manufactured by Aiphone.

LE-GAn-SS 0102

Page 2
Image 2
Aiphone LE-GA2, LE-GA8 specifications Standard Products, Stock Master Stations, P. Master Stations, Power Supplies