The NHX system with CODE BLUE has three priority levels:

Priority 1: Code Blue

Priority 2: Bath call and cord-out

Priority 3: Routine call

1. Code Blue call signal is a fast beep (1 per 0.5 seconds) and flashing LED (1 per 0.4 seconds). This signal is activated when the blue call switch on the NHR-7A-CB1 is moved to the lower

position, and will continue until it's reset to the upper position.

2.The Bath/Cord out signal is a single beep (1 per 2 seconds) and a double-blinking LED (2 blinks every 1.8 seconds). This signal is activated when the bath pull cord (NHR-7A) is moved to the lower position, or when the handheld call button (NHR-8A) is pulled out of the station. The call signal will remain until the master answers the call, at which time the tone will be reset. The blinking LED will remain until the bath station is reset to the upper position or the handheld call button is plugged back into the station.

3.The Routine call signal is a single beep (1 per 6 seconds) and a blinking LED (1 per 2 seconds). This signal is activated when the button is pressed on the handheld call cord, and is reset when the master station answers the call or when the CANCEL button on the patient station is pressed.

4.To place a CODE BLUE CALL, activate the Code Blue Station located near the patient station by pulling the attached cord or sliding the blue call switch down.

5.To reset the CODE BLUE CALL, move the blue call switch to the upper position.

Aiphone Communication Systems

TOLL FREE TECHNICAL SUPPORT:

 

(800) 692-0200

 

1700 130th Ave. N.E.

 

Extensions 8107, 8118, 8111

 

Bellevue, WA 98005

 

(425) 455-0510

TOLL FREE FAX LINE:

NH-1SA-ACB-BLU Instr

FAX: (425) 455-0071

(800) 832-3765

090104JS

Page 2
Image 2
Aiphone NH-1SA-ACB-BLU, NH-1SA-AC-BLU instruction sheet Operations