Operating 2055D |
|
| The desired value can be adjusted in increments of 5% | |
|
|
|
| by pressing button B. When selecting the humidity output, |
C | D | E | F | the desired value is blinking. The word DESIRED appears |
on the display (E). The setting for the relative humidity | ||||
ranges from a minimum of 30% to a maximum of 70%. | ||||
|
|
|
| CO means continuous use. A relative humidity of between |
|
|
|
| 40 and 60% is recommended. After a few seconds, the |
|
|
|
| display automatically changes to show the current value |
|
|
| H | (CURRENT) (E). Upon reaching the desired relative humi |
|
|
| dity, the unit automatically switches off (display shows | |
|
|
| DESIRED and CURRENT) (E). If the desired relative humi |
dity falls, the appliance automatically switches on again.
J G A B
A) Switching on/off
Turn rotary switch A from the G (off) position to position H or J as required. Position J is especially quiet (night mode). Po sition H (normal mode) achieves maximum humidity output. The disc rotation speed remains constant with both mode selections. The fan rotation speed increases with level II. As soon as the appliance is switched on, the display shows the current relative air humidity. The measurement is accurate to +/- 5%.
B) Setting the humidity output
The appliance is fitted with a hygrostat. This measures the relative air humidity and automatically switches the appli ance off when the desired value is reached.When switching the unit on use the rotary switch (A), the desired value is preset to 55%.
Quick display of current relative humidity
When the unit is switched off (cable is connected, rotary switch to position G (off)), the current relative humidity can be shown in the display by briefly pressing one of the B buttons. The display automatically disappears after a few seconds.
C) Change Ionic Silver Stick®
The symbol C in the display indicates that the Ionic Silver Stick® (ISS) must be changed. The symbol remains visible until both B buttons are pressed and held down for approx.
5seconds.
D)Cleaning the appliance
The symbol D in the display indicates that the appliance must be cleaned. Refer to section «Cleaning/maintenance» to learn more about how to clean your humidifier.The sym bol remains visible until both B buttons are pressed and held down for approx. 5 seconds.
E) Current/Desired Display
If DESIRED appears on the display, the value in % next to it signifies the desired relative humidity, i.e. the desired value is shown. If the display shows CURRENT, then the current relative humidity is shown.
F) Automatic | en |
«Tank empty» |
|
The water level is easy to see thanks to the transparent water tank. The display on the appliance also shows when the unit should be refilled with water. If the water level falls below the minimum level, the appliance automatically switches off. A red blinking symbol (F) appears on the dis play. When water is added, symbol F disappears and the appliance continues operating.
Warning: When lifting the upper part off the housing, the appliance also switches off. In this case, the red blinking F symbol will also appear on the display. Only when the up per part is replaced on the base does symbol F disappear and the appliance resumes operation.