Air-O-Swiss AOS 7147 setup guide Please Read First, Quick Set Up Guide Aos, Lifecycle Indicator

Models: AOS 7147

1 2
Download 2 pages 47.54 Kb
Page 1
Image 1
PLEASE READ FIRST

PLEASE READ FIRST

QUICK SET UP GUIDE AOS 7147

1

Finding the ideal location for your unit: Do not place the humidifier directly next to a heating or air vent.

2

The unit should be placed in an elevated position, e.g. on a table, chest, etc. at least 3 ft off the floor. Keep it away from doors or win- dows.

3

The mist outlet must not be pointed directly at plants or other objects. Keep a distance of at least 20 in- ches (50cm).

4

WARNING! Do not touch the water in the base during operation! Switch off the unit first. Place the Ionic Silver Stick in the base of the unit.

SOAK CARTRIDGE 24 HOURS BEFORE FIRST USE

5

24 h

Soak the demineralization cartridge in a water bath for 24 hours before the first use; the granules have to absorb water to reach high performance.

WARNING! If the cartridge is soaked in the tank, make sure to exchange the water and empty the water from the base before using the humidifier.

FILL THE TANK WITH FRESH COLD WATER

6

Take off the water tank cap to fill the tank with water.

7

Fill the tank with clean, cold water from the tap.

8

Do not pour water into the mist outlet of the appliance.

9

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Close the cap of the water tank

Insert the plug into the socket and

securely, place the water tank onto

switch on the appliance using the

the base. The water is now running

On/Off Dial.

from the tank into the base. The

 

empty indicator light may stay

 

illuminated for some seconds until

 

the base is filled with water.

 

QUICK OPERATION DESCRIPTION AOS 7147

H

E L F I D J

 

A

On/Off dial

H

Mist output indicator

A

B

Hygrostat (setting the humidity level)

I

Pre-heating indicator

G

C

Timer (1h – 8h or CO)

J

Automatic mode indicator

C

D

Mist output (regulating mist output)

K

Sleep mode indicator

M

E

Operation with pre-heating (warm mist)

L

Empty indicator

B

F

Automatic mode and Sleep mode

M

Cleaning indicator

KG Timer indicator

WATER QUALITY MAINTENANCE WITH IONIC SILVER STICK®

Water Quality Maintenance

The Ionic Silver Stick® (ISS) keeps the water free of microbial growth. The ISS uses the anti-microbial effect of silver to prevent the growth of microbes in the water base. It begins to function as soon as it comes into contact with water, even if the unit is switched off. The Ionic Silver Stick should be changed every year.

Lifecycle Indicator

Your appliance comes with a lifecycle indicator for changing the Ionic Silver Stick®. To remind yourself when you put the ISS into operation, please check the current month on the stamp and write the current year on the line provided.

DO NOT DISCARD! Save for future reference.

Please read the manual or check our website www.airoswiss.net for further information.

Page 1
Image 1
Air-O-Swiss AOS 7147 setup guide Please Read First, Quick Set Up Guide Aos, SOAK CARTRIDGE 24 HOURS BEFORE FIRST USE