Air King 4C630N/9012N specifications Read And Save These Instructions, Lista De Repuestos, Cant

Models: 4C630N/9012N 4C631P/9016P

1 4
Download 4 pages 59.51 Kb
Page 1
Image 1
MODELO 4C630N/9012N y 4C631P/9016P

MODELO 4C630N/9012N y 4C631P/9016P

OPERATING INSTRUCTIONS & PARTS MANUAL

4

23

22 18

5

 

1

 

2

 

3

 

32

 

31

 

33

 

34

6

30

35

WALL MOUNTED

OSCILLATING FANS

12" (30.4 cm) MODEL 4C630N/9012N 16" (40.6 cm) MODEL 4C631P/9016P

READ AND SAVE THESE INSTRUCTIONS

21

22

25

20

4 24

10

27

 

8

 

9

 

36

 

11

12

7

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

DESCRIPTION

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

circumstances must the grounding prong be cut off the plug.

 

Where a two-prong wall receptacle is encountered, it must be

18

19

 

28

26

37

7

 

AirKing 12" (30.4 cm) and 16" (40.6 cm) Wall Mounted Oscillating

Fans offer pull cord speed control, variable oscillation, a permanent

replaced with a properly grounded three-prong receptacle in-

stalled in accordance with the National Electrical Code (NEC)

split capacitor motor and OSHA-complying front steel mesh grill with

and all applicable local codes and ordinances. This work must

a 6 ft (1.8m) 18/3 cord set.

be done only by a qualified electrician, using copper wire only.

 

4

35

SPECIFICATIONS
WARNING: USE OF A THREE-PRONG TO TWO-PRONG

17

16

15

13

LISTA DE REPUESTOS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ref.

Parte No. for Modelo

 

 

14

 

 

 

 

No.

4C630M/9012M4C631N/9016NDescripciónCant.

1

2010119

2010119

Botón de Oscilación

1

 

 

2

02030062GL

02030066GL

Motor

1

 

3

2010665

2010665

Cubierta del Motor (Frontal)

1

 

 

 

4

02090040

02090040

Tornillo de la Cubierta Tipo B

 

 

 

 

 

 

 

 

 

 

#7 x 7/16" PTH

3

5

02090140

02090140

Tornillo de Enlace

2

 

 

 

6

2010276

2010276

Enlace

1

7

02010548A

02010548A

Boton Tipo H.C.

2

 

 

 

8

02010163

02010163

Cubierta de la Pieza del Cuello

1

9

02010162B

02010162B

Placa de Trinquete

1

 

10

2010165

2010165

Bola de Oscilación Doble con

 

 

 

 

 

 

 

 

 

 

Resorte

1

 

 

 

 

11

2010252

2010252

Pieza del Cuello

1

12

02090051

02090051

Tornillo Phillips de Cabeza

 

 

 

 

 

 

 

 

 

 

Reforzada #7 x .390 PTH

1

13

2010131

2010131

Botón del Interruptor (Rotatorio) 1

 

 

 

 

14

02050009AWFPC

02050009AWFPC

Cordón Eléctrico

1

 

15

02090744

02090744

Tire Cuerda

1

 

 

 

 

 

16

2090539

2090539

Casquillo del Cordón Accionador 1

17

02090272

02090272

Pata de Caucho

2

 

 

 

 

 

18

02090045A

02090045A

Tornillo Phillips Tipo 25 #8 x 3/4" 6

19

2010552

2010552

Tapa del Interruptor

1

 

 

 

 

 

20

2060202

2060202

Placa Tracera para Colgar

1

 

21

2060316

2060316

Placa de Montaje

1

 

 

 

 

22

2090003

2090003

Tornillo Phillips #8 x 1-1/4"

2

23

2090529

2090529

Tuerca para Alambre

2

 

24

02055047

02055047

Interruptor con Cordón

 

 

 

 

 

 

 

 

 

 

Accionador

1

 

 

 

 

 

25

2010512P

2010512P

Cuerpo

1

26

02090521A

02090521A

Eje de Elevación

1

 

 

 

 

27

02090518

02090518

Resorte de Elevación

1

28

02090033

02090033

Tuerca Hexagonal

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

29

2010661

2010661

Cubierta del Motor (Trasera)

1

 

30

07091657

07091657

Vástago del Motor

1

 

 

 

 

 

31

02090060

02090060

Tornillo #7 x .8 PPH ZP Tipo B

2

 

32

2011212

2011200M

Rejilla Plástica Trasera

1

 

 

33

2010359

2010359

Tuerca de la Rejilla

1

 

34

2010008

2011013

Paletas

1

 

 

 

35

2010058

2010059

Tapa

1

 

36

02096217

02096214I

Rejilla Frontal

1

 

37

02010381A

02010381A

Ornamento de la Rejilla

1

Motor

 

 

 

120V, 60 Hz (12", 30.4 cm)

 

 

 

 

 

 

120V, 60 Hz (16", 40.6 cm)

 

Blade diameter

12" ( 30.4 cm) Model 4C630N/9012N

 

 

 

 

 

16" (40.6 cm) Model 4C631P/9016P

Speeds

..............................

 

 

3

 

 

 

 

 

Control

..............................

 

 

Pull Cord

 

 

 

 

Air flow distribution

...........

90°

 

 

 

 

 

Approvals

UL Listed. Close mesh Fan Guard

 

 

 

 

 

meets OSHA requirements.

 

 

 

 

 

 

 

 

 

 

 

 

MODEL

4C630N/9012N

 

4C631P/9016P

 

 

SPEED

HIGH

 

MED

LOW

 

HIGH

MED

 

LOW

 

CFM

930

 

780

620

 

1710

1500

 

1330

 

M3/s

0.44

 

0.37

0.29

 

0.80

0.71

 

0.63

 

RPM

1450

 

1300

1090

 

1545

1394

 

1244

 

Amps

0.40

 

0.30

0.27

 

0.71

0.54

 

0.48

 

Watts

39

 

35

32

 

77

65

 

57

 

 

 

 

 

 

 

 

 

 

 

 

dBA

45

 

41

36

 

53

49

 

44

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precau- tions should always be followed to reduce the risk of fire, electric shock and injury to person, including the following:

1.Read all instructions before using Fan.

2.Make certain that the power source conforms to the electrical requirements of the Fan.

3.Use this Fan only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electrical shock, or injury to persons.

4.Unplug power cord before installing, servicing, or moving the Fan.

WARNING: DO NOT DEPEND UPON THE ON-OFF SWITCH AS THE SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR SERVICING THE FAN. ALWAYS UNPLUG THE POWER CORD.

5.This Fan must NOT be used in potentially dangerous locations such as flammable, explosive, chemical-laden or wet atmospheres.

6.DO NOT use Fan in or near a window. Rain may create an electrical hazard.

7.The power cord is equipped with a three-prong grounded plug that must be inserted into a matching receptacle. Under no

ADAPTER IS NOT RECOMMENDED. IMPROPER CON- NECTION MAY CREATE THE RISK OF ELECTROCUTION. USE OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA. WARNING: THIS PLUG IS A SAFETY FEATURE. TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND PERSONAL INJURY, DO NOT REMOVE, REPLACE, REPAIR OR TAMPER WITH THE ORIGINALLY SUPPLIED PLUG. IF THE FAN DOES NOT FUNCTION PROPERLY, IT MAY BE DUE TO THE SAFETY DEVICE INCORPORATED IN THIS PLUG. RETURN TO AN AUTHORIZED SERVICE CENTER OR CALL 800-233-0268, MONDAY - FRIDAY, BETWEEN 8:30 AM AND 4:00 PM EST. IF THE PLUG WARNING LABEL IS MISSING OR DAMAGED, CALL THE TOLL FREE NUMBER FOR A REPLACEMENT LABEL.

8.Where possible, avoid the use of extension cords. If they must be used, minimize the risk of overheating by ensuring that they are UL listed. Never use a single extension cord to operate more than one Fan.

9.Do not operate any Fan with a damaged cord or plug or after the Fan malfunctions, has been dropped or damaged in any manner. Return Fan to authorized service facility for examination, electrical or mechanical adjustment or repair.

10.Do not insert or allow fingers or foreign objects to enter any ventilation or exhaust opening as it may cause an electric shock or fire, or damage the Fan. Do not block or tamper with the Fan in any manner while it is in operation.

11.Always place the Fan on a stable, flat, level surface when operating, to avoid the chance of the Fan overturning. Locate the Power Cord so the Fan or other objects are not resting on it. Do not run Power Cord under carpeting. Do not cover Power Cord with throw rugs, runners, or the like. Arrange Power Cord away from room traffic and where it will not be tripped over.

12.This Fan is not intended for use in wet or damp locations. Never locate a Fan where it may fall into a bathtub or other water container.

13. Do not use Fan outdoors.

WARNING: REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK – DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICES.

SAVE THESE

INSTRUCTIONS

Rev. P 3/05

8

2084060A

 

Rev. P 3/05

1

2084060A

Page 1
Image 1
Air King 4C630N/9012N specifications Read And Save These Instructions, Operating Instructions & Parts Manual, Description