Air King specifications Read And Save These Instructions, MODELO 4TM65A/9530A, Notas

Models: 4TM65A/9530A

1 4
Download 4 pages 19.69 Kb
Page 1
Image 1
MODELO 4TM65A/9530A

MODELO 4TM65A/9530A

NOTAS

OPERATING INSTRUCTIONS & PARTS MANUAL

9" HIGH PERFORMANCE PIVOT FAN9" (22.8 cm) MODEL 4TM65A/9530A

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
DESCRIPTION

The Airking 9" (22.9 cm) high performance pivot fan features 3-speed rotary knob operation with 112° adjustable tilt stand. The 9" ( 22.9 cm) 3-paddle blade is driven by a permanent prelubricated motor with a 6' (1.83 m) 18/3 cordset

SPECIFICATIONS

Motor

120V, 60 Hz

 

 

Blade Diameter

9" ( 22.9 cm)

 

 

Speeds

3

 

 

 

 

Control

Rotary Knob

 

 

Air Flow Distribution

112° Variable

 

 

Approvals

UL listed. Close mesh fan guard meets

 

 

OSHA requirements.

 

 

 

 

 

 

 

 

MODEL

4TM65A/9530A

 

 

 

SPEED

HIGH

MED

 

LOW

 

 

CFM

700

610

 

520

 

 

M3/s

0.33

0.29

 

0.25

 

 

RPM

2100

1800

 

1500

 

 

 

 

 

 

 

 

 

Amps

0.50

0.43

 

0.37

 

 

Watts

58

51

 

45

 

 

 

 

 

 

 

 

 

dB A

54

50

 

46

 

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precau- tions should always be followed to reduce the risk of fire, electric shock and injury to person, including the following:

1.Read all instructions before using Fan.

2.Make certain that the power source conforms to the electrical requirements of the Fan.

3.Use this Fan only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electrical shock, or injury to persons.

5.Unplug power cord before installing, servicing, or moving the Fan.

WARNING: DO NOT DEPEND UPON THE ON-OFF SWITCH AS THE SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR SERVICING THE FAN. ALWAYS UNPLUG THE POWER CORD.

6.This Fan must NOT be used in potentially dangerous locations such as flammable, explosive, chemical-laden or wet atmospheres.

7.DO NOT use Fan in or near a window. Rain may create an electrical hazard.

replaced with a properly grounded three-prong receptacle in- stalled in accordance with the National Electrical Code (NEC) and all applicable local codes and ordinances. This work must be done only by a qualified electrician, using copper wire only.

WARNING: USE OF A THREE-PRONG TO TWO-PRONG ADAPTER IS NOT RECOMMENDED. IMPROPER CON- NECTION MAY CREATE THE RISK OF ELECTROCUTION. USE OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA. WARNING: THIS PLUG IS A SAFETY FEATURE. TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND PERSONAL INJURY, DO NOT REMOVE, REPLACE, REPAIR OR TAMPER WITH THE ORIGINALLY SUPPLIED PLUG. IF THE FAN DOES NOT FUNCTION PROPERLY, IT MAY BE DUE TO THE SAFETY DEVICE INCORPORATED IN THIS PLUG. RETURN TO AN AUTHORIZED SERVICE CENTER OR CALL 800-233-0268, MONDAY - FRIDAY, BETWEEN 8:00 AM AND 5:00 PM EST. IF THE PLUG WARNING LABEL IS MISSING OR DAMAGED, CALL THE TOLL FREE NUMBER FOR A REPLACEMENT LABEL.

8.Where possible, avoid the use of extension cords. If they must be used, minimize the risk of overheating by ensuring that they are UL listed. Never use a single extension cord to operate more than one Fan.

9.Do not operate any Fan with a damaged cord or plug or after the Fan malfunctions, has been dropped or damaged in any manner. Return Fan to authorized service facility for examination, electrical or mechanical adjustment or repair.

10.Do not insert or allow fingers or foreign objects to enter any ventilation or exhaust opening as it may cause an electric shock or fire, or damage the Fan. Do not block or tamper with the Fan in any manner while it is in operation.

11.Always place the Fan on a stable, flat, level surface when operating, to avoid the chance of the Fan overturning. Locate the Power Cord so the Fan or other objects are not resting on it. Do not run Power Cord under carpeting. Do not cover Power Cord with throw rugs, runners, or the like. Arrange Power Cord away from room traffic and where it will not be tripped over.

12.This Fan is not intended for use in wet or damp locations. Never locate a Fan where it may fall into a bathtub or other water container.

13. Do not use Fan outdoors.

WARNING: REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK – DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICES.

Rev. E 7/05

8

 

that must be inserted into a matching receptacle.

Under no

SAVE THESE

 

2. The power cord is equipped with a three-prong grounded plug

INSTRUCTIONS

 

circumstances must the grounding prong be cut off the plug.

 

 

 

Where a two-prong wall receptacle is encountered, it must be

 

2084532

Rev. E 7/05

1

2084532

Page 1
Image 1
Air King 4TM65A/9530A specifications Read And Save These Instructions, Operating Instructions & Parts Manual, Notas