Wiring

Wiring

1.Make connections to low voltage wire from inlet to inlet in parallel. Connect any low voltage wire along trunk and branch lines using suitable wire connectors. Connect the low voltage wire to crimp connectors located on the top outside of the power unit (Figure 23).

Low Voltage

 

Wire

 

 

Low Voltage

 

Wire

Crimp

 

Connector

 

Power Unit Lead

 

To Other

 

Inlets

 

Figure 23

Inlets

2. Plug the power unit’s grounded cord into a 120 volt grounded receptacle.

Check the System

1.Make sure all inlets are closed and the collection canister is in place. Switch the power on using the manual power switch on the power unit to test.

2.Test the inlets by inserting the power hose. The power unit should turn on and begin suctioning. Check for any air leaks in the system.

Maintenance

CAUTION: MAKE SURE POWER UNIT IS UNPLUGGED BEFORE SERVICING THE UNIT.

1.The only regular maintenance your system will need is for the collection canister to be emptied. Usage will dictate how often this needs to be done. To empty the canister, release the two clips on either side of the canister and slide off. When reinstalling, make sure the canister is properly seated in the rubber gasket.

2.Your unit is equipped with a self cleaning filter and it should not be removed. If an excess of debris has built up on the filter you can simply shake it off. It is recommended that you place a large plastic garbage bag under the unit when doing this.

CAUTION: DO NOT USE GASOLINE, BENZINE, THINNER, HARSH CLEANSERS, ETC., AS THEY MAY DAMAGE THE RANGE HOOD. NEVER USE ALCOHOL OR SOLVENTS.

3.If the power unit needs to be cleaned, use a damp towel with a mild detergent, such as dishwashing liquid, and dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS. Use caution when cleaning around motor area and DO NOT allow water to enter into motor chamber. Completely dry the unit before connecting to power source. NEVER IMMERSE

ELECTRICAL PARTS IN WATER.

LIMITED WARRANTY

All products manufactured by Air King Limited are warranted for one year from the date of purchase against defects in workmanship and/or material. In addition, all ventilating/exhaust fans, heaters, combination fan lights and/or heaters, and range hoods are guaranteed for five years from the date of purchase against defects in workmanship and/or material.

This warranty does not cover any labor or shipping costs or the cost of replacement components as part of routine maintenance such as: range hood grease filters, charcoal filters or combination charcoal/grease filters; replacement light bulbs in range hoods or bathroom fan/light/bulb heater combinations. As well, any damage or failure caused by abuse, misuse, abnormal usage, faulty installation, or improper maintenance will not be covered by this warranty.

In order to make a claim on this warranty, you must be the original consumer of the product. You will be required to present to Air King the original bill of sale showing: date of purchase, place of purchase and model purchased. Failure to meet these requirements will void your warranty.

Air King will not be held responsible for any bodily injury or damages to personal property or real estate whether caused directly or indirectly by the product. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages and some states do not allow limitations on how long an implied warranty lasts, so these exclusions or limitations may not apply to you. This warranty gives you specific legal rights and you may have other rights which vary from state to state and province to province.

Troubleshooting Guide

Trouble

 

Probable Cause

 

Suggested Remedy

1.

Unit will not turn on

1.

Power unit is not plugged in.

1.

Plug power unit in.

 

 

2.

Fuse or circuit breaker blown or OFF.

2.

Check main and branch fuse or circuit breaker.

 

 

3.

Loose connection in wiring to inlets.

3.

Check wire connections to the inlet to insure proper connection.

 

 

 

 

 

 

2.

Loss of suction power

1.

Collection canister is full.

1.

Check to see if collection canister needs to be emptied.

 

 

2.

Collection canister not properly installed.

2.

Check to make sure canister is properly seated in rubber gasket.

 

 

3.

Blockage in the hose.

3.

Use a long blunt object to clear the blockage

 

 

4.

Blockage in the pipe.

4. Check at inlet location for any obstructions. If the blockage is further

 

 

 

 

 

into the system, contact your local dealer for assistance.

 

 

 

 

 

 

FOR PARTS OR TECHNICAL ASSISTANCE

Please call: 1-800-465-7300,MONDAY THROUGH FRIDAY, BETWEEN THE HOURS OF 8 AM AND 4:00 PM EST.

PLEASE DO NOT RETURN PRODUCT TO PLACE OF PURCHASE.