2.Using the included 8-32 screws and washers, mount the blower in place and tighten all screws. Confirm that the blower is securely seated in place and there are no air gaps around the blower gasket.

3.Plug both the 3 wire and 4 wire quick connect cords from the blower into the appropriate receptacles located on the inside front of the hood canopy. These cords will only fit into the receptacles one way (Figure 2).

4.Plug both the 3 wire and 4 wire quick connect cords from the blower into the appropriate receptacles located on the inside front of the hood canopy. These cords will only fit into the receptacles one way (Figure 2).

5.Reinstall the rear bottom plate by fitting the back edge of the plate into the channel located on the back of the hood and reinstalling the two screws and washers removed in Step 1 (Figure 4).

 

Receptacles

Screw

 

Washer

 

 

 

 

Channel

Figure 2

Blower

Bottom Plate

Figure 4

 

SECTION 3

 

 

 

Installation into 10" High Canopy

SECTION 4

1. Remove the rear bottom plate of the hood canopy. It is secured in place

Finishing the Installation

 

with a screw and washer on either side (Figure 3).

1. Install the included fuse into the electrical panel by turning the fuse cap

 

Screw

counter clockwise and pulling out. Insert the included 1/4" x 1-1/4" time

 

delay fuse in the holder and reinstall into the panel (Figure 5).

 

Washer

 

 

 

Cap

 

Bottom Plate

Fuse

 

 

 

Figure 3

 

2.

Lift blower up into the hood canopy and slide the keyhole slots in the blower

Figure 5

 

mounting flange over the two studs of the hood. Slide the blower into place

 

 

and tighten the hex nuts on the mounting stud while lining up the 8 holes

NOTE: If you need to replace the fuse, replace with a 1/4" x 1-1/4" Bussman

in the blower mounting flange to the 8 screw studs of the hood (Figure 1).

MDA-3 or equivalent 3 amp, 250V ceramic, time delay fuse only.

3. Using the included 8-32 screws and washers, mount the blower in place

2.

Refer to the hood instruction manual to complete the installation, for

and tighten all screws. Confirm that the blower is securely seated in place

 

maintenance, and before restoring power.

and there are no air gaps around the blower gasket.

 

3.

The blower is covered under the range hood’s warranty.

 

REPLACEMENT PARTS DIAGRAM

#

Qty.

Description

Replacement Part #

 

1

1

Blower Assembly

5S1136063

 

2

1

Blower Gasket

5S1136100

 

3

8

Grommet

5S1136101

 

4

8

Washer

5S1136102

 

5

8

8-32 Screw

5S1136103

8

6

1

Capacitor

5S1136104

 

7

1

Screw

5S1136105

 

8

1

Fuse

5S1136106

 

 

 

 

 

5

3

4

2

6

7

1

111597005 New 3-07

www.airkinglimited.com

2 of 8

Page 2
Image 2
Air King B600 Replacement Parts Diagram, Receptacles Screw Washer, Blower Bottom Plate, Washer Cap Bottom Plate Fuse

B600 specifications

The Air King B600 is a standout model in the world of ventilation and air conditioning solutions, specifically designed to meet the needs of both residential and commercial spaces. Recognized for its superior functionality, durability, and energy efficiency, it is an ideal choice for those seeking reliable airflow and ventilation.

One of the primary features of the Air King B600 is its robust motor, which provides exceptional airflow while maintaining low noise levels. The fan operates at varying speeds, allowing users to customize airflow based on their specific needs. With a powerful airflow rating, the B600 ensures that even large areas are adequately ventilated, making it perfect for workshops, garages, and other expansive environments.

The fan is equipped with advanced technologies that enhance its performance. One notable technology is its built-in thermostat, which enables automatic operation based on the temperature of the surrounding area. This feature not only maximizes comfort levels but also contributes to energy savings by ensuring the fan operates only when necessary. The B600 also incorporates a high-quality motor that is designed for longevity, reducing the need for frequent replacements and maintenance.

Durability is another strong characteristic of the Air King B600. Constructed from high-quality materials, this fan is resistant to wear and tear from continuous use. The finish is often rust-resistant, making it suitable for various environments, including those with high humidity or exposure to harsh elements.

Installation of the B600 is straightforward, thanks to its user-friendly design. It can be mounted on walls or ceilings, providing flexibility in terms of placement. This versatility allows users to optimize airflow and ventilation according to the unique layout of their space.

Furthermore, the Air King B600 adheres to modern energy efficiency standards, helping users reduce their environmental footprint. By consuming less power while delivering powerful performance, it is a cost-effective solution for consumers looking to lower their energy bills without compromising on quality.

In summary, the Air King B600 integrates advanced technologies, powerful airflow capabilities, durable construction, and energy efficiency into a compact and user-friendly design. Whether for residential or commercial applications, the B600 stands out as an exceptional choice for efficient ventilation and air circulation.