2.Using the included 8-32 screws and washers, mount the blower in place and tighten all screws. Confirm that the blower is securely seated in place and there are no air gaps around the blower gasket.

3.Plug both the 3 wire and 4 wire quick connect cords from the blower into the appropriate receptacles located on the inside front of the hood canopy. These cords will only fit into the receptacles one way (Figure 2).

4.Plug both the 3 wire and 4 wire quick connect cords from the blower into the appropriate receptacles located on the inside front of the hood canopy. These cords will only fit into the receptacles one way (Figure 2).

5.Reinstall the rear bottom plate by fitting the back edge of the plate into the channel located on the back of the hood and reinstalling the two screws and washers removed in Step 1 (Figure 4).

 

Receptacles

Screw

 

Washer

 

 

 

 

Channel

Figure 2

Blower

Bottom Plate

Figure 4

 

SECTION 3

 

 

 

Installation into 10" High Canopy

SECTION 4

1. Remove the rear bottom plate of the hood canopy. It is secured in place

Finishing the Installation

 

with a screw and washer on either side (Figure 3).

1. Install the included fuse into the electrical panel by turning the fuse cap

 

Screw

counter clockwise and pulling out. Insert the included 1/4" x 1-1/4" time

 

delay fuse in the holder and reinstall into the panel (Figure 5).

 

Washer

 

 

 

Cap

 

Bottom Plate

Fuse

 

 

 

Figure 3

 

2.

Lift blower up into the hood canopy and slide the keyhole slots in the blower

Figure 5

 

mounting flange over the two studs of the hood. Slide the blower into place

 

 

and tighten the hex nuts on the mounting stud while lining up the 8 holes

NOTE: If you need to replace the fuse, replace with a 1/4" x 1-1/4" Bussman

in the blower mounting flange to the 8 screw studs of the hood (Figure 1).

MDA-3 or equivalent 3 amp, 250V ceramic, time delay fuse only.

3. Using the included 8-32 screws and washers, mount the blower in place

2.

Refer to the hood instruction manual to complete the installation, for

and tighten all screws. Confirm that the blower is securely seated in place

 

maintenance, and before restoring power.

and there are no air gaps around the blower gasket.

 

3.

The blower is covered under the range hood’s warranty.

 

REPLACEMENT PARTS DIAGRAM

#

Qty.

Description

Replacement Part #

 

1

1

Blower Assembly

5S1136063

 

2

1

Blower Gasket

5S1136100

 

3

8

Grommet

5S1136101

 

4

8

Washer

5S1136102

 

5

8

8-32 Screw

5S1136103

8

6

1

Capacitor

5S1136104

 

7

1

Screw

5S1136105

 

8

1

Fuse

5S1136106

 

 

 

 

 

5

3

4

2

6

7

1

111597005 New 3-07

www.airkinglimited.com

2 of 8