![Screw](/images/new-backgrounds/92312/923125x1.webp)
Screw |
Washer |
Bottom Plate |
Figure 5 |
2.Install transformer into hood canopy by lining up the 2 holes on the flange of the transformer with the 2 screw studs in the top left side of the hood canopy. Use 2 of the included
3.Attach the capacitor to the blower by lining up the two holes on the flange of the capacitor with the holes on the blower. Use the 2 included #6 screws to make the connection and fully tighten (Figure 2).
4.Lift blower up into the hood canopy and slide the keyhole slots in the blower mounting flange over the two studs of the hood. Slide the blower into place and tighten the hex nuts on the mounting stud while lining up the 8 holes in the blower mounting flange to the 8 screw studs of the hood (Figure 3).
5.Using 8 of the included
6.Plug the 3 wire quick connect cord from the blower into the receptacle on the range hood canopy. Plug the 4 wire quick connect cord from the blower into the receptacle on the transformer. Connect one end of the wiring harness to the connector coming out of the transformer and the other end to the receptacle in the range hood canopy. These cords will only fit into the receptacles one way (Figure 4).
7.Reinstall the rear bottom plate by fitting the back edge of the plate into the channel located on the back of the hood and reinstalling the two screws and washers removed in Step 1 (Figure 6).
Screw |
|
Washer | Channel |
| |
Bottom Plate |
|
Figure 6 |
|
SECTION 4
Finishing the Installation
1.Install the included fuse into the electrical panel by turning the fuse cap counter clockwise and pulling out. Insert the included 1/4" x
Cap |
Fuse |
Figure 7 |
NOTE: If you need to replace the fuse, replace with a 1/4" x
2.Refer to the hood instruction manual to complete the installation, for maintenance, and before restoring power.
3.The blower is covered under the range hood’s warranty.
111597006 New | www.airkinglimited.com | 3 of 12 |