INSTALLATION INSTRUCTIONS

CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION.

WARNING: THIS BLOWER IS INTENDED FOR USE ONLY IN AIR KING PROFESSIONAL SERIES RANGE HOOD CANOPIES MARKED SUITABLE FOR USE WITH THIS BLOWER. DO NOT TO INSTALL IN ANY OTHER APPLICATION.

SECTION 1

Preparing for installation

NOTE: Before installing blower, make sure range hood canopy is properly installed and securely in place. See “Range Hood Mounting Instructions”.

1.Unpack blower from the carton and confirm that all pieces are present. In addition to the blower you should have:

10 - 8-32 Screws

8 - Washers

1 - Capacitor

2 - #6 Screws

1 - Transformer

1 - Fuse

1- Instruction/Safety Sheet

2.The installation of the blower is slightly different from one canopy height to another. For 18" high canopies proceed to Section 2, for 10" high canopies proceed to Section 3.

3.Lift blower up into the hood canopy and slide the keyhole slots in the blower mounting flange over the two studs of the hood. Slide the blower into place and tighten the hex nuts on the mounting stud while lining up the 8 holes in the blower mounting flange to the 8 screw studs of the hood (Figure 3).

Stud w/Hex Nuts

Screw Stud

Keyholes

Figure 3

4.Using 8 of the included 8-32 screws and washers, mount the blower in place and tighten all screws. Confirm that the blower is securely seated in place and there are no air gaps around the blower gasket.

5.Plug the 3 wire quick connect cord from the blower into the receptacle on the range hood canopy. Plug the 4 wire quick connect cord from the blower into the receptacle on the transformer. Plug the 4 wire quick connect from the transformer into the receptacle on the range hood canopy. These cords will only fit into the receptacles one way (Figure 4).

SECTION 2

Installation into 18" High Canopy

1.Install transformer into hood canopy by lining up the 2 holes on the flange of the transformer with the 2 screw studs in the top left side of the hood canopy. Use 2 of the included 8-32 screws to make the connection and fully tighten (Figure 1).

Figure 1

Transformer

Rear Wall

 

 

 

Receptacles

Blower

Transformer

Figure 4

SECTION 3

2. Attach the capacitor to the blower by lining up the two holes on the

Installation into 10" High Canopy

 

flange of the capacitor with the holes on the blower. Use the 2 included

1. Remove the rear bottom plate of the hood canopy. It is secured in

#6 screws to make the connection and fully tighten (Figure 2).

 

 

place with a screw and washer on either side (Figure 5).

 

Figure 2

Capacitor

 

 

 

 

 

111597006 New 3-07

www.airkinglimited.com

2 of 12

Page 2
Image 2
Air King B900, B1125 manual Stud w/Hex Nuts, Transformer, Receptacles, Capacitor

B1125, B900 specifications

Air King has long been a prominent name in ventilation and exhaust fan technology, and their B900 and B1125 models showcase the brand's commitment to effective air circulation and efficient design. These fans are designed for various applications, including residential, commercial, and industrial settings, offering unique features and technologies that set them apart from their competitors.

The Air King B900 is a powerful exhaust fan that boasts a sleek, compact design. This model is equipped with a high-efficiency motor that delivers exceptional performance while remaining energy-efficient. The B900 features a unique blade design that enhances airflow, ensuring that spaces remain well-ventilated without unnecessary noise. With an air movement capacity of 900 CFM (cubic feet per minute), it is an excellent choice for larger rooms, including kitchens and bathrooms, where moisture and odors can accumulate.

One standout feature of the B900 is its easy installation process, allowing homeowners to mount it in various configurations. It also comes with a built-in damper, which prevents backdrafts, ensuring that outside air does not infiltrate the room when the fan is not in use. This model is particularly well-suited for individuals looking to upgrade their ventilation systems without extensive renovations.

On the other hand, the Air King B1125 is designed for those needing even more powerful ventilation. It offers an impressive air movement capacity of 1125 CFM, making it ideal for larger commercial spaces or facilities that require maximum air exchange. The B1125 features a robust construction, designed for durability and longevity even in demanding environments.

This model also incorporates advanced technology, including a multi-speed operation and a thermal overload protection system. These features allow users to adjust the fan speed based on specific requirements, providing tailored ventilation while optimizing energy consumption. The B1125 is also equipped with a corrosion-resistant housing, making it suitable for both indoor and outdoor installations.

Both models prioritize noise reduction, ensuring that users enjoy a quiet yet effective operation. Their thoughtful design and engineering make the Air King B900 and B1125 pivotal choices for anyone needing reliable and efficient ventilation solutions. With a blend of performance, technology, and user-friendliness, Air King continues to innovate and lead the way in the ventilation industry.