What is a Fire Rated Exhaust Fan?
The Air King Fire Rated Exhaust Fan Series consists of a three part system designed to meet the NFPA’s (National Fire Protection Association) Standard 90A. The unit consists of a Housing, a Ceiling Radiation Damper that is ULC Classified and rated for 3 - 4 hour fire resistance, and the Motor/Blade/Grill. When all three of these parts are used together they create a Fire Rated Exhaust Fan.
What does a Fire Rated Exhaust Fan Do?
The Fire Rated Exhaust Fan Series is designed to automatically shut off and seal the duct from the rest of the dwelling once the temperature of air passing through the damper exceeds that of the fusible link. This prevents the spread of smoke or fire through the ducting system to the other rooms or dwellings.
Why do I need a Fire Rated Exhaust Fan?
Your local code will dictate if and what type of Fire Rated Exhaust Fan you will need. Generally any time a common duct is used in a
Deluxe Quiet Fire
Rated Exhaust Fan
Series
The Deluxe Quiet Fire Rated Exhaust Fan Series Series combines style and quiet operation with
a Ceiling Radiation Damper.
•Grill: Cold rolled steel, powder coated white.
•Blower Wheel: One piece polymeric centrifugal blower wheel, 5 7/32" diameter, 2 29/32" wide, with 30 blades.
•Motor: Heavy duty, permanently split capacitor, 4 pole motor, life time lubrication, thermally protected.
•Fan Housing: 24 gauge galvanized steel housing.
•Duct Collar: Metal collar for 4" duct connection, comes complete with built in back draft damper.
•Unit Mounting: Unit is centered between joists (with 16" centers) using hanging brackets. The housing will mount through drywall thickness up to 3/4".
•Damper:
Blanket -
•Availability: Single Packs or sold in Contractor Packs of 4
(Housing, Damper, Motor/Blade/Grill).
Model | Motor | Housing | Damper | CFM/Sones | RPM | HVI |
@ PS.1 WG | Sones | |||||
FRAK80 | FAK80T | AKFH2 | AKFD2 | 80/2.6 | 1250 | 1.5 |
FRAK90 | FAK90T | AKFH2 | AKFD2 | 90/2.9 | 1250 | 2.0 |
FRAK110 | FAK110T | AKFH2 | AKFD2 | 110/3.5 | 1250 | 2.5 |
FRAK130 | FAK130T | AKFH2 | AKFD2 | 120/3.6 | 1250 | 3.0 |
Performance shown is for FRAK exhaust models for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille, ceiling radiation damper and backdraft damper in the airstream. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The loudness ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA standard 301. Values shown are for installation type B: free inlet fan sone levels. The AMCA Certified Ratings Seal does not apply to HVI Sones.
Advantage 4" Duct
Fire Rated Exhaust
Fan Series
The Advantage 4" Duct Fire Rated Exhaust Fan Series combines high performance with a Ceiling Radiation Damper.
•Grill: Cold rolled steel, powder coated white.
•Blower Wheel: One piece polymeric wheel, 5 7/32" diameter, 2 3/8" wide, with 48 blades.
•Motor: Heavy duty,
•Fan Housing: 24 gauge galvanized steel housing.
•Duct Collar: Metal collar for 4" duct connection, comes complete with built in back draft damper.
•Unit Mounting: Unit is centered between joists (with 16" centers) using hanging brackets. The housing will mount through drywall thickness up to 3/4".
•Damper:
Blanket -
•Availability: Single Packs or sold in Contractor Packs of 4
(Housing, Damper, Motor/Blade/Grill).
CFM/Sones HVI Model Motor Housing Damper @ PS.1 WG RPM Sones
FRAS90 | FA90T | AKFH2 | AKFD2 | 90/3.1 | 1250 | 2.5 |
FRAS120 | FA120T | AKFH2 | AKFD2 | 120/3.7 | 1300 | 3.0 |
Performance shown is for FRAK exhaust models for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille, ceiling radiation damper and backdraft damper in the airstream. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The loudness ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA standard 301. Values shown are for installation type B: free inlet fan sone levels. The AMCA Certified Ratings Seal does not apply to HVI Sones.
Specifications subject to change without notice.
CUS
Air King Ventilation Products certifies that the models shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the Certified Ratings Program.
Specifications subject to change without notice.