Airstream 18 owner manual Slot, Fan Inlet Bolt Circle

Models: 18

1 26
Download 26 pages 63.93 Kb
Page 8
Image 8
Slot

LTD HEATER INSTALLATION

INSTALLING THE LTD HEATER WITH LTD MOUNTING BRACKETS

THESE INSTRUCTIONS ARE FOR HEATER INSTALLATION ON FAN UNITS WITH 230V MOTORS.

BE SURE POWER IS

DISCONNECTED AND LOCKED OUT BEFORE INSTALLATION! FAILURE TO DO SO MAY CAUSE SERIOUS INJURY OR DEATH.

1. Place heater on the ground next

to the inlet of the centrifugal fan.

The LTD heater is designed to

mount upwind. Be sure airflow

decal is pointing towards the in-

let of the fan.

2. Bolt LTD mounting brackets to

each of the six holes in the

downstream angle ring of the

heater. Snug tighten bolts such

that they can still pivot with little

IMPORTANT!

Note: Heater Direction

Figure 1: Make sure the LTD Heater is positioned in the right direction.

Figure 2: The six(6) mounting brackets positioned on the LTD Heater.

force applied. See chart for slots

to bolt through in bracket.

Slot

Fan Inlet Bolt Circle

 

 

End

31" to 35"

Middle

Less than 31"

 

 

3.Pivot brackets so they are nearly radial from center of heater. Stand behind heater and deter mine which bolts on fan inlet best line up with the brackets. Remove the nuts from those

six(6) bolts and bolt the remain- ing six(6) brackets to fan using nuts removed. It may be neces- sary to remount the fan grill guard so mounting brackets will seat properly. Slots to use for fan mounting bolts are below.

Slot

Fan Inlet Bolt Circle

 

 

End

35"

Middle

31 3/4"

Inner

29"

 

 

Figure 3: The LTD Heater brackets pivoted so they are radial from the center of the heater.