LTD HEATER INSTALLATION

4.Lift heater and align paired brackets as shown and insert bolts in corresponding slots as in table below. Be sure to place washer provided between tap and bracket. Tighten bolts snug but loose enough to slide heater in and out.

 

Slot

 

Fan HP

Heater

 

Fan

 

 

 

 

5

Middle

 

Middle

7.5

End

 

Middle

10

End

 

Middle

15

End

 

End

20

End

 

End

25

End

 

End

 

 

 

 

5.Align mating bracket pairs so that they are in a straight line. Tighten bolts on fan and heater rigid.

6.Make sure the heater stand off dimension is correct for the fan used. Refer to the table below. Slide the heater to meet the stand off dimension all around. Tighten mating brackets rigid. The heater should now be se- curely fastened to the fan. If not tighten all loose connections.

Fan HP

Stand Off

5

 

5"

7.5

 

7"

10

 

7"

15

7

1/2"

20

8

1/2"

25

8

1/2"

 

 

 

Figure 4: Heater aligned with paired brackets and bolts inserted.

Figure 5: Align mating bracket pairs in a straight line.

IMPORTANT!

Figure 6: Check the heater stand off distance, based on fan horsepower.

9