SERVICE

Problem

Possible Cause

 

 

Burner operates-But will not cycle from hi-fire to lo-fire.

1.Check the gas pressure reading on the gauge. Problem may be due to insufficient gas regulator setting. Tempo- rarily decrease the hi-lo fire thermostat setting to verify that the thermostat will function and cause the burner to cycle. If burner will cycle at the reduced thermostat setting, it indicates that the problem was due to insuffi- cient heat to satisfy the original setting. Increase the gas regulator setting for additional heat output. Do not exceed the maximum pressure listed in this manual.

2.Hi-lo fire thermostat control may be defective. If the burner still will not cycle to lo-fire after decreasing the thermostat, the problem may be due to a broken or kinked thermostat sensor tube. Observe reading on the thermometer. Replace control assembly if it cannot be set to cause its switch to go to the open circuit position with normally hot air plenum temperatures.

3.If the burner continues to operate on hi-fire, check the hi-fire gas solenoid valve for a stuck or blocked open condition, or for reversed gas pipe connections. The solenoid valve must not allow gas flow when its coil is not energized.

Burner operates-But will not cycle from lo-fire to hi-fire.

1.Check for an excessive lo-fire gas pressure setting. Observe pressure setting shown on gauge, and compare reading with recommended low pressure settings listed in this manual. Readjust lo-fire setting on flow control valve, if necessary.

2.Check for improperly adjusted or defective hi-lo fire thermostat control. Temporarily increase the tempera- ture setting. If the heater will still not cycle, check for problem in the control wire connections. The control wires should be connected to terminals R and B of the thermostat, so the switch will open upon temperature rise. If the burner will cycle with these two wires connected together, the thermostat is faulty.

3.Check for improperly connected or faulty hi-fire gas vapor solenoid valve. Correct any poor connections or defective wiring. If wiring appears proper, problem may be caused by a burned out valve coil or defective valve. Replace hi-fire solenoid valve, or its coil, if defective.

50

Page 50
Image 50
Airstream PNEG-339 service manual Service

PNEG-339 specifications

The Airstream PNEG-339 is a highly regarded model in the realm of agricultural storage and handling equipment, specifically designed for grain management. Its innovative features and robust technologies make it a valuable asset for farmers and grain handlers seeking efficiency and reliability.

One of the primary characteristics of the PNEG-339 is its seamless construction. Built with high-quality materials, the unit is engineered to withstand the rigors of outdoor environments while providing durable protection for stored grains. The design minimizes maintenance requirements, ensuring that users can focus on their core agricultural operations without the distraction of frequent repairs.

The PNEG-339 is equipped with advanced aeration systems that enhance the preservation of grain quality. This technology allows for optimal airflow circulation, reducing moisture levels and minimizing the risk of spoilage. By maintaining the ideal conditions for grain storage, farmers can ensure better yields and profitability.

Another notable feature of the PNEG-339 is its scalability. This model can easily be integrated into existing grain handling systems, accommodating various storage capacities. Whether managing small-scale operations or large agricultural enterprises, the PNEG-339 offers flexibility in design and implementation, making it suitable for diverse agricultural needs.

The unit also boasts user-friendly controls and monitoring systems, allowing operators to manage grain conditions efficiently. Real-time data and automated alerts assist in maintaining optimal storage conditions, thus reducing labor costs and enhancing operational efficiency. As a result, farmers can make informed decisions quickly and effectively.

Additionally, the PNEG-339 incorporates energy-efficient technologies that contribute to sustainability in agriculture. By utilizing energy-saving components, this model not only lowers operational costs but also aligns with the growing emphasis on environmentally responsible farming practices.

Overall, the Airstream PNEG-339 stands out as a top-tier choice for grain storage and handling. With its durable construction, advanced aeration systems, scalability, user-friendly controls, and energy efficiency, it meets the demands of modern agricultural operations. Its design and functionality reflect a commitment to quality and performance, making it an essential tool for those in the agricultural sector aiming to enhance their productivity and maintain the integrity of their grain stores.