Alcatel-Lucent ES4 Series IEEE standard compliance, IETF specifications, Dimensions, Power supply

Models: ISA-ES1 ES4 Series

1 6
Download 6 pages 15.55 Kb
Page 6
Image 6
IEEE standard compliance

IEEE standard compliance

IEEE 802.1d Spanning Tree

IEEE 802.1p Priority Queuing

IEEE 802.1q VLAN Tagging

IEEE 802.1w Rapid Spanning Tree

IEEE 802.1s Multiple Spanning Tree

IEEE 802.1ad Provider Edge Bridges

IEEE 802.3ad Link Aggregation

IEEE 802.1ag Ethernet OA&M

IEEE 802.3 Ethernet Physical Layer

¬Clauses 24-25 100Base-T

¬Clauses 13-14 10Base-T

¬Clauses 28 Autonegotiation

IEEE 802.3u FE

IEEE 802.3x Flow Control

IEEE 802.3z GigE

IEEE 802.3ah Ethernet in First Mile

IETF specifications

General

RFC 768 User Datagram Protocol

RFC 783 Trivial File Transfer Protocol (TFTP)

RFC 791 Internet Protocol

RFC 792 Internet Control Message Protocol

RFC 793 Transmission Control Protocol

RFC 826 Ethernet Address Resolution Protocol

RFC 854 Telnet Protocol Specification

RFC 1122 Requirements for Internet HostsComm Lay

RFC 1518 Classless Inter-Domain Routing

RFC 1519 Classless Inter-Domain Routing

RFC 1542/951 Clarifications and Extensions to the Bootstrap Protocol

RFC 1812 Requirements for IPv4 Routers

Differentiated Services (DiffServ)

RFC 2474 Definition of the Differentiated Services Field (DS Field) in IPv4 and IPv6 Headers

RFC 2475 DiffServ Core and Edge Routing Functions

RFC 2597 DiffServe Assured Forwarding

RFC 3140 Per Hop Behavior Identification (PHB) Codes

RFC 3246/2598 Expedited Forwarding PHB

Dimensions

One basic card slot consuming in 1642 EM, 1642 EMC,1640 FOX, 1650 SMC, 1662 SMC and 1660 SM

Power supply

-36-V to -75-V DC (-48-V)

Redundant, hot-swappable

Power consumption: 20 W maximum

Environmental

Class 3.2 ETSI: partly temperature-controlled locations

Support information

Support for ISA-ES1 is provided through the Alcatel-Lucent Global Technical Support Organization with specifying information on hardware and software hosting equipment.

Please refer to www.Alcatel- Lucent.com to contact Alcatel- Lucent’s worldwide support organizations.

www.alcatel -lucent.comAlcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners. The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein. © 2008 Alcatel-Lucent. All rights reserved. CAR2468080270 (04)