The water flow control can be fine tuned to help tightly control the specific characteristics of your particular still, and can help regulate varying input water pressures. There are four different presets that can be chosen for use during operation.
To change the water flow rate control, turn on the EB120, and press and release the Drain key on the remote. The Temperature Display will flash and show one of four pressure settings; 1PS, 2PS, 3PS, 4PS.
Press the Drain key one or more times to cycle through the four choices. When you see the selection you want, press the Enter key to confirm. The Temperature display will stop flashing and return to displaying the temperature reading of the still.
Finally, you MUST now press the On/Off button and turn the EB120 off, then press the On/Off button once more and turn the unit back on. These steps are required to store the new setting, and to prevent accidental changing of the water flow rate to the still.
Chapter Five: Troubleshooting guide
Please note that we recommend all repairs are carried out be a suitably qualified person.
Trouble description | Possible Cause | Solution(s) | |||
When the boiler is | Check: |
| 1. | Check power supply voltage. | |
turned on there is |
| 1. | Power supply | 2. | If the indicator LED of power supply isn’t on, |
no display on |
| 2. | Transformer |
| then check transformer or power supply. |
control panel. |
| 3. | Main circuit | 3. | If the LED remains red, remove the controller |
|
|
| board |
| turn off, reinstall the controller, and restart. |
|
| 4. | Controller | 4. | Change circuit board |
|
| 5. | Control cable or | 5. | Check the control cable port and controller. |
|
|
| port |
|
|
System appears to | Check: |
| (1) | Indicator LED for beer level is red. Check beer | |
be turned on, but | 1. | Beer supply. |
| input supply | |
the boiler is not | 2. | Beer pump | (2) | Check the connection of water level probe. | |
heating. |
| operation. | (3) | Check ground wire connection of circuit board | |
| 3. | Water level probe |
| and boiler. | |
| 4. | Main board | (4) | Indicator LED for beer level is green. Check | |
| 5. | Ground wire of boiler |
| circuit board | |
|
| and circuit board | (5) | Check if overheat switch is disconnected | |
| 6. | Heating control | (6) | Check heating elements | |
|
| board |
|
| |
| 7. | Heating elements |
|
| |
EB120 is turned on, | Check: |
| Possibly need to: |