Operation
TMB2136N
Figure 6
Dual Digital Timer Control
RQ Control Suffix
1.Select HIGH, MED, LOW or NO HEAT by turning the temperature knob.
2.Set the HEAT TIME for the number of minutes (from 0-60) desired.
3.Set the COOL DOWN TIME for the number of minutes (from 0-15) desired.
4.Select reversing or nonreversing cylinder rotation setting, if applicable.
5.Press and release START button to start tumbler. Display will show minutes remaining before end of cycle.
NOTE: One touch drying is available for repetitive loads. If the START button is pressed while the machine is in Idle Mode, when the display is dark, the tumbler will repeat the last drying cycle. If the cycle time is adjusted before the cycle is started, the time displayed when the start button was pressed will be used for future cycles.
IMPORTANT: To stop the tumbler at any time during the cycle, OPEN DOOR. If the loading door or lint panel door is opened during the cycle, the heating system will shut off and the motor will stop. To restart the cycle, both doors must be closed and the START button must be pressed in.
If the load cools to 90° F before cool down time expires, the control will flash “Lr” (load ready) in the heat time display. If the door is not opened, the tumbler completes the selected cool down time. If the door is opened after reaching “Lr” temperature, the cycle will be terminated.
NOTE: If display shows an error code, refer to Error Codes section.
6.When the cycle is complete, open door and remove the laundry.
NOTE: This machine includes an
12 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 70283501 |