To Program a Short Test Cycle:

1.Unplug machine power cord.

2.Write down machine control dip switch settings,

then set them all to the off position. Refer to Figure 7.

3. Plug machine in and start a cycle.

NOTE: With all control dip switches off, the total cycle time will be 1 minute long.

4. Once all testing is complete, unplug machine and re-set dip switches to their original settings.

5. Plug machine in.

Error Codes

WARNING

Operation

O 1 2 3 4 5 6 7 8

N

12345678

TMB2216N

Figure 7

To reduce the risk of electric shock, fire, explosion, serious injury or death:Disconnect electric power to the tumbler before servicing.Close gas shut-off valve to gas tumbler before servicing.Close steam valve to steam tumbler before servicing.Never start the tumbler with any guards/panels removed.

Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded.

 

 

W002

 

 

 

 

 

 

Display

Definition

Corrective Action

 

 

 

 

Open thermistor error

Check thermistor. Replace if inoperative.

 

 

Check wiring diagram between control and

OP

 

thermistor. Refer to wiring diagram for proper

 

 

wiring.

 

 

Check control. Replace if inoperative.

 

 

 

 

Shorted thermistor error

Check thermistor. Replace if inoperative.

SH

 

Check wiring between control and thermistor.

 

Refer to wiring diagram for proper wiring.

 

 

 

 

Check control. Replace if inoperative.

 

 

 

AF - 1

Airflow switch closed when cycle

Check airflow switch. Replace if inoperative.

started

 

 

 

 

 

 

AF - 2

Airflow switch failed to close after

Check airflow switch. Replace if inoperative.

cycle started

 

 

 

 

 

 

70283501

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

13