STEP 3: (Gas Dryer ONLY)

Connect Gas Supply Pipe

For further assistance, refer to Section on Gas Requirements.

1.Make certain dryer is equipped for use with the type of gas in laundry room. Dryer is equipped at the factory for Natural Gas with a 3/8" NPT gas connection.

2.Remove the shipping cap from the gas connection at the rear of the dryer. Make sure you do not damage the pipe threads when removing the cap.

3.Connect to gas supply pipe.

4.Tighten all connections securely. Turn on gas and check all pipe connections (internal & external) for gas leaks with a non-corrosive leak detection fluid.

5.For L.P. (Propane) gas connection, refer to Section on Gas Requirements.

NEW

STAINLESS STEEL

FLEXIBLE

CONNECTOR

USE ONLY

IF ALLOWED

BY LOCAL

CODES (Use

Design A.G.A.

Certified

Connector)

3/8" NPT

GAS CONNECTION

BLACK IRON PIPE Shorter than 6.1 m (20') - use 3/8" pipe Longer than 6.1 m (20') - use 1/2" pipe

1/8" NPT

PIPE PLUG

(For checking

inlet gas pressure)

EQUIPMENT

SHUT-OFF

VALVE Install within

1.8 m (6') of dryer

D233IE3H

12

504523