Location Requirements . . .

Select a location with a solid floor.

No other fuel burning appliance should be installed in the same closet with the dryer.

The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

Leveling legs can be adjusted from inside the dryer with a 1/4" driver. All four legs must rest firmly on the floor so

the weight of the dryer is evenly distributed. The dryer must not rock.

The dryer needs sufficient clearance and an adequate air supply for proper operation and ventilation, and for easier installation and servicing. (Minimum clearances are shown below.)

F

CLOSET

 

 

 

DOOR

 

 

 

B

 

 

 

 

 

 

CENTERED

 

 

 

AIR

 

 

E

OPENINGS (G)

 

D

(2 Openings

 

 

 

 

Minimum)

 

 

 

A

 

**42"

 

 

 

 

F

A

A

C

FRONT VIEW

SIDE VIEW

(w/o Closet Door)

 

OUTER

WALL OF

ENCLOSURE

FRONT VIEW (Closet Door)

D337IE3A

AREA

DESCRIPTION

FREE STANDING /

CLOSET INSTALLATION

 

 

ALCOVE INSTALLATION

(See Illustration)

 

 

(See Illustration)

 

 

 

 

 

A

Dryer sides and rear clearance

0 cm (0")

0 cm (0")

B

Dryer top clearance

30.5 cm (12")

30.5 cm (12")

 

 

 

 

C

Dryer front clearance

Not Applicable

5.1 cm (2")

D

Exhaust duct clearance to

5.1 cm (2")

5.1 cm (2")

 

combustible material

 

 

 

 

 

 

E

Weather hood to ground

30.5 cm (12")

30.5 cm (12")

 

clearance

 

 

 

 

 

 

F

Distance from floor or ceiling

Not Applicable

7.6 cm (3")

 

to hole edge

 

 

 

 

 

 

G*

Area of centered air openings

Not Applicable

260 sq. cm/open (40 sq. in.)

 

in closet door

 

 

 

 

 

 

*Louvered door with equivalent air openings is acceptable. (Minimum clearances are shown.)

**NOTE: For new installations, locate top of wall vent 106 cm (42 inches) above floor to make venting easier to connect.

20

504523