A dryer exhausts 214 cfm (measured at back of dryer) and sufficient
An unobstructed opening of at least 260 cm2 (40 square inches) of outdoor
If it is necessary to duct
Exhaust System
IMPORTANT: Keep exhaust duct as short as possible.
NOTE: Be certain old ducts are cleaned before installing your new dryer.
For best drying results, recommended maximum length of exhaust system is shown below.
To prevent backdraft when dryer is not in operation, outer end of exhaust pipe must have a weather hood with hinged dampers (obtain locally).
NOTE: Weather hood should be installed at least 30.5 cm (12 inches) above the ground. Larger
clearances may be necessary for installations where heavy snowfall can occur.
Exhaust Direction
The dryer can be exhausted to the outdoors through the back, left, right or bottom of the dryer. EXCEPTION:
Gas dryers cannot be vented out the left side because of the burner housing.
Dryer is shipped from factory ready for rear exhaust; no kits required.
Exhausting the dryer through sides or bottom can be accomplished by installing a Directional Exhaust Kit 528P3 available as optional equipment at extra cost.
D361IE0A
528P3 Directional Exhaust Kit
Number of |
| Weather Hood Type |
90° Elbows |
|
|
Recommended | Use only for short run installations |
| 10.16 cm | 6.35 cm |
| |
10.16 cm | (4") | D011IE2Q | ||
(4") | D011IE2P | |||
|
Maximum length of 10.2 cm (4") diameter rigid metal duct.
0 |
| 13.4 m (44 feet) |
| 10.4 m (34 feet) |
1 |
| 10.4 m (34 feet) |
| 7.9 m (26 feet) |
2 |
| 7.9 m (26 feet) |
| 6.1 m (20 feet) |
3 |
| 6.1 m (20 feet) |
| 4.3 m (14 feet) |
| Maximum length of 10.2 cm (4") diameter flexible metal duct. | |||
0 |
| 7.3 m (24 feet) |
| 6.1 m (20 feet) |
|
| |||
1 |
| 6.1 m (20 feet) |
| 4.9 m (16 feet) |
2 |
| 4.9 m (16 feet) |
| 3.7 m (12 feet) |
3 |
| 3.7 m (12 feet) |
| 2.4 m (8 feet) |
|
|
|
|
|
NOTE: Deduct 1.8 m (6 feet) for each additional elbow.