Basic Installation/Operation
Electrical Specifications
|
|
|
|
|
| Electrical Specifications |
|
|
|
|
|
| |||||
|
| Voltage Designation |
|
|
|
| Standard |
| Electric Heat | ||||||||
Model | Code | Voltage | Cycle |
| Phase |
| Wire | Full Load Amps |
| Circuit Breaker |
| AWG /mm | Full Load Amps |
| Circuit Breaker |
| AWG /mm |
|
|
|
|
|
|
|
|
|
|
|
| 2 |
|
|
|
| 2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
18 | N | 50/60 |
| 3 |
| 3+PE | 6 |
| 15 |
| 14/2.5 | 20 |
| 25 |
| 10/6.0 | |
| P | 50/60 |
| 3 |
| 3+N+PE |
| Not available |
| 17 |
| 20 |
| 12/4.0 | |||
| Q | 50/60 |
| 3 |
| 3+PE |
| Not available |
| 28 |
| 30 |
| 10/6.0 | |||
| X | 50/60 |
| 1/3 |
| 2/3+PE | 10 |
| 15 |
| 14/2.5 |
| Not available |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| N | 50/60 |
| 3 |
| 3+PE | 6 |
| 15 |
| 14/2.5 | 21 |
| 25 |
| 10/6.0 | |
25 | P | 50/60 |
| 3 |
| 3+N+PE |
| Not available |
| 18 |
| 20 |
| 12/4.0 | |||
Q | 50/60 |
| 3 |
| 3+PE |
| Not available |
| 29 |
| 30 |
| 10/6.0 | ||||
|
|
|
|
|
|
| |||||||||||
| X | 50/60 |
| 1/3 |
| 2/3+PE | 10 |
| 15 |
| 14/2.5 |
| Not available |
| |||
| N | 50/60 |
| 3 |
| 3+PE | 6 |
| 15 |
| 14/2.5 | 32 |
| 40 |
| 8/10.0 | |
33 | P | 50/60 |
| 3 |
| 3+N+PE | 18 |
| 20 |
| 12/4.0 | 44 |
| 50 |
| 8/10.0 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Q | 50/60 |
| 3 |
| 3+PE | 18 |
| 20 |
| 12/4.0 | 63 |
| 70 |
| 4/25.0 | ||
|
|
|
|
|
|
| |||||||||||
| X | 50/60 |
| 1/3 |
| 2/3+PE | 18 |
| 20 |
| 12/4.0 |
| Not available |
| |||
| N | 50/60 |
| 3 |
| 3+PE | 12 |
| 15 |
| 14/2.5 | 41 |
| 50 |
| 8/10.0 | |
35 | P | 50/60 |
| 3 |
| 3+N+PE |
| Not available |
| 36 |
| 40 |
| 8/10.0 | |||
Q | 50/60 |
| 3 |
| 3+PE |
| Not available |
| 58 |
| 60 |
| 6/16.0 | ||||
|
|
|
|
|
|
| |||||||||||
| X | 50/60 |
| 1/3 |
| 2/3+PE | 12 |
| 15 |
| 14/2.5 |
| Not available |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| N | 50/60 |
| 3 |
| 3+PE | 6 |
| 15 |
| 14/2.5 | 32 |
| 40 |
| 8/10.0 | |
40 | P | 50/60 |
| 3 |
| 3+N+PE | 18 |
| 20 |
| 12/4.0 | 44 |
| 50 |
| 8/10.0 | |
Q | 50/60 |
| 3 |
| 3+PE | 18 |
| 20 |
| 12/4.0 | 63 |
| 70 |
| 4/25.0 | ||
|
|
|
|
|
|
| |||||||||||
| X | 50/60 |
| 1/3 |
| 2/3+PE | 18 |
| 20 |
| 12/4.0 |
| Not available |
| |||
| N | 50/60 |
| 3 |
| 3+PE | 12 |
| 15 |
| 14/2.5 | 41 |
| 50 |
| 8/10.0 | |
55 | P | 50/60 |
| 3 |
| 3+N+PE |
| Not available |
| 36 |
| 40 |
| 8/10.0 | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Q | 50/60 |
| 3 |
| 3+PE |
| Not available |
| 58 |
| 60 |
| 6/16.0 | ||||
|
|
|
|
|
|
| |||||||||||
| X | 50/60 |
| 1/3 |
| 2/3+PE | 16 |
| 20 |
| 14/2.5 |
| Not available |
| |||
| N | 50/60 |
| 3 |
| 3+PE | 12 |
| 15 |
| 14/2.5 | 41 |
| 50 |
| 8/10.0 | |
75 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
P | 50/60 |
| 3 |
| 3+N+PE | 12 |
| 15 |
| 14/2.5 | 36 |
| 40 |
| 8/10.0 | ||
| Q | 50/60 |
| 3 |
| 3+PE | 15 |
| 20 |
| 12/4.0 | 58 |
| 60 |
| 6/16.0 | |
| N | 50/60 |
| 3 |
| 3+PE | 17 |
| 20 |
| 12/4.0 | 62 |
| 70 |
| 4/25.0 | |
100 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
P | 50/60 |
| 3 |
| 3+N+PE | 17 |
| 20 |
| 12/4.0 | 55 |
| 60 |
| 6/16.0 | ||
| Q | 50/60 |
| 3 |
| 3+PE | 18 |
| 25 |
| 10/6.0 | 88 |
| 90 |
| 3/35.0 | |
| N | 50/60 |
| 3 |
| 3+PE | 17 |
| 25 |
| 10/6.0 | 62 |
| 70 |
| 4/25.0 | |
135 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
P | 50/60 |
| 3 |
| 3+N+PE | 17 |
| 25 |
| 10/6.0 | 55 |
| 60 |
| 6/16.0 | ||
| Q | 50/60 |
| 3 |
| 3+PE | 20 |
| 30 |
| 10/6.0 | 88 |
| 90 |
| 3/35.0 | |
| N | 50/60 |
| 3 |
| 3+PE | 20 |
| 25 |
| 10/6.0 |
| Not available |
| |||
165 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
P | 50/60 |
| 3 |
| 3+N+PE | 20 |
| 25 |
| 10/6.0 |
| Not available |
| ||||
| Q | 50/60 |
| 3 |
| 3+PE | 32 |
| 40 |
| 8/10.0 |
| Not available |
| |||
|
|
|
|
|
|
| Table 3 | (continued) |
|
|
|
|
|
|
|
|
28 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 9001014 |