Basic Installation/Operation

Machine Foundation

Thoroughness of detail must be stressed with all foundation work to ensure a stable unit installation. eliminating possibilities of excessive vibration during extract.

CAUTION

Ensure that the machine is installed on a level floor of sufficient strength and that the recommended clearances for inspection and maintenance are provided. Never allow the inspection and maintenance space to be blocked.

W488

The washer-extractor must be placed on a smooth level surface so that the entire base of the machine is supported and rests on the mounting surface.

The standard installation does not require anchoring unless mandated by state or local codes.

Static and dynamic loads on the floor or foundation are shown in Table 2.

Table 2 can be used as a reference when designing floors and foundations.

Floor Load Data

Model

18

25

33

35

40

55

75

100

135

165

200

 

 

 

 

 

 

 

 

 

 

 

 

Kinetic Energy of

 

 

 

 

 

 

 

 

 

 

 

the Cylinder,

1386

1730

2736

3240

4105

6640

12404

18361

23257

29581

29581

(N/m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dynamic Bottom

700/16

750/16

1200/16

1200/16

1200/16

1700/15

2000/15

2960/13

3900/13

4960/13

6100/13

Load, (N/Hz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 2

 

 

 

 

 

 