Installation

Machine Foundation

Thoroughness of detail must be stressed with all foundation work to ensure a stable unit installation, eliminating possibilities of excessive vibration during extract.

CAUTION

Ensure that the machine is installed on a level floor of sufficient strength and that the recommended clearances for inspection and maintenance are provided. Never allow the inspection and maintenance space to be blocked.

SW020

The washer-extractor must be placed on a smooth level surface so that the entire base of the machine is supported and rests on the mounting surface. (Do not support the washer- extractor on only four points.)

The 35-pound, 50-pound, and 85-pound capacity washer-extractors do not require anchoring unless mandated by state or local codes.

Static and dynamic loads on the floor or foundation are shown in the table below. This table can be used as a reference when designing floors and foundations.

Floor Load Data

 

35

50

85

 

 

 

 

Static floor load, lbs (kN)

1453 (6.47)

1929 (8.58)

3452 (15.4)

 

 

 

 

Static pressure, lbs-ft2(kN-m2)

153 (7.32)

172 (8.23)

214 (10.3)

 

 

 

 

Dynamic floor load, lbs (kN)

150 (0.67)

200 (0.89)

400 (1.78)

 

 

 

 

Maximum dynamic load, lbs (kN)

150 (0.67)

200 (0.89)

400 (1.78)

 

 

 

 

Dynamic pressure, lbs-ft2(kNm2)

15.8 (0.76)

17.9 (0.86)

24.8 (1.19)

 

 

 

 

18

F232058