Installation
Machine Foundation
Thoroughness of detail must be stressed with all foundation work to ensure a stable unit installation, eliminating possibilities of excessive vibration during extract.
CAUTION
Ensure that the machine is installed on a level floor of sufficient strength and that the recommended clearances for inspection and maintenance are provided. Never allow the inspection and maintenance space to be blocked.
SW020
The
The
Static and dynamic loads on the floor or foundation are shown in the table below. This table can be used as a reference when designing floors and foundations.
Floor Load Data
| 35 | 50 | 85 |
|
|
|
|
Static floor load, lbs (kN) | 1453 (6.47) | 1929 (8.58) | 3452 (15.4) |
|
|
|
|
Static pressure, | 153 (7.32) | 172 (8.23) | 214 (10.3) |
|
|
|
|
Dynamic floor load, lbs (kN) | 150 (0.67) | 200 (0.89) | 400 (1.78) |
|
|
|
|
Maximum dynamic load, lbs (kN) | 150 (0.67) | 200 (0.89) | 400 (1.78) |
|
|
|
|
Dynamic pressure, | 15.8 (0.76) | 17.9 (0.86) | 24.8 (1.19) |
|
|
|
|
18
F232058