Installation

Rear Panel

1/4-20 Fiberlock Nut

1/4-20 x 5/8 Screw

Recirculation

Adapter Plate

1/4-20 Fiberlock Nut

1/4-20 Fiberlock Nut

1/4-20 x 5/8 Screw

No. 48

Hose Clamp

Wet Clean Drain Adapter Plate

1/4-20 x 5/8 Screw

1/4-20 Fiberlock Nut

Flex Drain Hose

Base Frame

Recirculation inlet hose

No. 28 Hose Clamp

Capped with Rubber Plug

Before Inlet Hose Installation

Shell

Capped with Sump

Plug Before Hose

Installation

Recirculation

Drain Outlet

Sump

Inner Drain Hose

No. 48

Hose Clamp

Premium Wet Clean Module Installation – Internal Plumbing

Z015I3A

Figure 20

4.Wiring the drain valve on the canister/ filter/pump assembly (See Drawing No. 633583, included with kit):

a.Remove drain valve motor cover on the washer-extractor.

b.Extend 2-conductor cable already installed on the drain valve on the canister/pump/filter assembly to the left drain valve on the washer-extractor.

c.Splice 2-conductor cable with the left drain valve motor leads, using the blue female quick-disconnect terminals included in the kit.

34

F232058