Maintenance
Daily (Continued)
End of Day
1.Clean the AC drive box filter(s):
a.Snap off the external plastic cover which contains the filter. The
b.Remove the foam filter from the cover.
c.Wash the filters with warm water and allow to air dry. Filters can be vacuumed clean.
2.Clean motor cooling fan filter:
a.Snap off the external plastic cover which contains the filter. Remove the foam filter from the cover.
b.Wash the filter in a mild soap solution or vacuum it clean.
3.Clean the door gasket of residual detergent and all foreign matter.
4.Clean automatic supply dispenser and lid inside and out with mild detergent. Rinse with clean water.
5.Clean the washer’s top, front, and side panels with mild detergent. Rinse with clean water.
6.Leave loading door open at the end of each day to allow moisture
to evaporate.
Note: Unload the machine promptly after each completed cycle to prevent moisture buildup. Leave loading door open at the end of each completed cycle to allow moisture to evaporate.
46
Weekly
1.Check the machine for leaks.
a.Start an unloaded cycle to fill the machine.
b.Verify that door and door gasket do not leak.
c.Verify that the drain valve is operating. If water does not leak out during the prewash segment, drain valve is closed and functioning properly.
Monthly
Note: Disconnect power to the machine
at its source before performing the monthly maintenance procedures.
1.Each month OR after every 200 hours of operation, lubricate bearings and seals. (Locate the bearing lubrication decal behind the external supply unit on the top right of the machine.)
a.Use a
b.Pump the grease gun slowly, permitting only the following number of strokes:
•Bearing grease fitting, 2 strokes
•Seal grease fitting, 1 stroke
Do not pump the grease gun until grease comes out of the bearing housing. This can result in overlubrication, causing damage to bearings and seals.
F232058